Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: KEITH SANDERS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of KEITH SANDERS in LOT 112, TOWNSHIP AT COLONY PARK, RIDGELAND, MS 39158 (NAICS 238350). OSHA activity number 338801434.

Watch Keith Sanders — free Get an email when a new federal OSHA severe-injury report for Keith Sanders is published. One employer, no account, unsubscribe in one click.
Establishment
KEITH SANDERS
Site address
LOT 112, TOWNSHIP AT COLONY PARK
City
RIDGELAND
State
MS
ZIP
39158
Mailing
135 SUNNY LAND, FLORENCE, MS 39073
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238350
Employees
3
Ownership type
A

7 citations on file for this inspection.

1926.405 J01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $960.00 Reduced
29 CFR 1926.405(j)(1)(i):   Live parts. Fixtures, lampholders, lamps, rosettes, and receptacles shall have no live parts normally exposed to employee contact. However, rosettes and cleat-type lampholders and receptacles located at least 8 feet (2.44 m) above the floor may have exposed parts.  (a) Lot 112, The Township at Colony Park, Ridgeland MS - On or about February 8, 2013 employees were using a blue, 4 outlet, electrical receptacle that had exposed electrical parts. The receptacle did not have a cover and a knock out plug located on the back of the receptacle box was missing.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1926.451 C02

Serious Gravity 5 4 instances 2 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $960.00 Reduced
29 CFR 1926.451(c)(2):   Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.  (a) Lot 112, The Township at Colony Park, Ridgeland MS - On or about February 8, 2013 employees were working from welded frame scaffolds that did not have base plates.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1926.451 C02 I

Serious Gravity 5 4 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(c)(2)(i):   Footings shall be level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement.  (a) Lot 112, The Township at Colony Crossing, Ridgeland MS - On or about February 8, 2013 employees were working from welded frames that were not sitting on level and rigid foundations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 G01

Serious Gravity 5 4 instances 2 exposed
Issued
Abate by
Penalty
Initial $2400.00 · Current $1440.00 Reduced
29 CFR 1926.451(g)(1):   Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level.   (a) Lot 112, The Township at Colony Park, Ridgeland MS - On or about February 8, 2013 employees were working from welded frame scaffolds that were 17 feet high without having any fall protection.
Recent events (2)
  • — I (S) $1440
  • — Z (S) $2400

1926.405 E01

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(e)(1):   Cabinets, fittings, and boxes. Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations shall be installed so as to prevent moisture or water from entering and accumulating within the enclosures. In wet locations the enclosures shall be weatherproof.  (a) Lot 112, The Township at Colony Park, Ridgeland MS - On or about February 8, 2013 employees were using a blue, 4 outlet, electrical receptacle that was not enclosed to prevent water from entering and accumulating inside the receptacle box.  The receptacle was used outside in a damp environment.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.405 G02 IV

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(g)(2)(iv):   Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.  (a) Lot 112, The Township at Colony Park, Ridgeland MS - On or about February 8, 2013 employees were using an extension cord that had the outer sheathing pulled away from the plug.  A circular saw was plugged into the extension cord.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.405 I02

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(i)(2):   Uses permitted. Fixture wires may be used: For installation in lighting, fixtures and in similar equipment where enclosed or protected and not subject to bending or twisting while in use.  (a) Lot 112, The Township at Colony Park, Ridgeland MS - On or about February 8, 2013 a blue, 4 outlet, electrical receptacle was connected to an indoor electrical wire (Romex) and was subjected to bending and twisting.  The indoor electrical wire was being used in the same manner as a flexible cord.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338801434.