LYNN, MA —
OSHA Inspection: ENTERPRISE CONSTRUCTION LLC DBA ENTERCON CONSTRUCT
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ENTERPRISE CONSTRUCTION LLC DBA ENTERCON CONSTRUCT in 131-143 BROAD STREET, LYNN, MA 01901 (NAICS 236220). OSHA activity number 338849235.
Where did this inspection happen?
- Establishment
- ENTERPRISE CONSTRUCTION LLC DBA ENTERCON CONSTRUCT
- Site address
- 131-143 BROAD STREET
- City
- LYNN
- State
- MA
- ZIP
- 01901
- Mailing
- 24 PORTLAND STREET, WORCESTER, MA 01608
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 6
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.62 D01 I
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1926.62(d)(1)(i): Each employer who had a workplace or operation covered by 29 CFR 1926.62 did not initially determine if any employee was exposed to lead at or above the action level of 30 micrograms per cubic meter of air (30 g/m3) calculated as an 8-hour time-weighted average (TWA): Location: 131-143 Broad Street, Lynn MA 01901 On or about 2/13/2013, The employer failed to determine if any employee may be exposed to lead at or above the action level while demolishng the internal walls of a structure.
Recent events (1)
- — Z (S) $2000
1926.403 B02
- Issued
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: (a) Location - 131-143 Broad Street, Lynn, MA: On or about 3/12/13, employees were exposed to electrical shock and burns and fire hazards while using a relocatable power tap not rated for construction use.
Recent events (1)
- — Z (S) $2000
1926.403 I02 I
- Issued
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph. (a) Location - 131-143 Broad Street, Lynn, MA: On or about 3/12/13, the employer did not adequately protect employees from electrical shock from exposed energized lamp holders and an electrical panel.
Recent events (1)
- — Z (S) $2000
1926.405 A02 II E
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(E): Lamps used in temporary wiring for general illumination were not protected from accidental contact or breakage: (a) Location 131-143 Broad Street, Lynn, MA: 3rd floorOn or about 3/12/13, the employer failed to ensure lamps used for temporary illumination were protected from accidental breakage.
Recent events (1)
- — Z (S) $0
1926.501 B04 II
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1926.501(b)(4)(ii): Each employee on a walking/working surface was not protected from tripping in or stepping into or through holes (including skylights) by covers: (a) Location - 131-143 Broad Street, Lynn, MA: On or about 3/12/13, employees were not protected from falling while working in close proximity to uncovered floor holes.
Recent events (1)
- — Z (S) $1600
1926.1052 C01 I
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: (a) Location - 131-143 Broad Street, Lynn, MA: On or about 3/12/13, employees were ascending and descending stairwells that did not have at least one handrail.
Recent events (1)
- — Z (S) $1600
1926.1053 B04
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: (a) Location -131-143 Broad Street, Lynn, MA: On or about 3/12/13, a stepladder was used in the closed position.
Recent events (1)
- — Z (S) $1600
More inspections at ENTERPRISE CONSTRUCTION LLC DBA ENTERCON CONSTRUCT
WORCESTER, MA—2010-11-03 00:00:00
ENTERPRISE CONSTRUCTION LLC DBA ENTERCON CONSTRUCT
WEST ROXBURY, MA—2010-08-19 00:00:00
ENTERPRISE CONSTRUCTION LLC DBA ENTERCON CONSTRUCT
View ENTERPRISE CONSTRUCTION LLC DBA ENTERCON CONSTRUCT's full OSHA safety record →
More inspections in this industry (NAICS 236220)
IRVINE, CA—2026-07-13
SNEARY CONSTRUCTION, INC.
IRVINE, CA—2026-07-13
KUKBO DESIGN USA LLC
SIOUX FALLS, SD—2026-07-13
REM CONSTRUCTION SERVICES, LLC
INDIAN ROCKS BEACH, FL—2026-07-10
UNKNOWN CONTRACTOR
SIOUX FALLS, SD—2026-07-10
HENRY CARLSON COMPANY
More inspections in MA
WORCESTER, MA—2026-07-10
QUINSIGAMOND COMMUNITY COLLEGE
FITCHBURG, MA—2026-07-10
KELLEY WOOD PRODUCTS, INC.
EVERETT, MA—2026-07-10
HORIZON RETAIL CONSTRUCTION INC
NORTON, MA—2026-07-09
DYNAMIC RESIDENTIAL ROOF MARKETING, LLC
NORTON, MA—2026-07-09
LM GENERAL CONSTRUCTION INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338849235.