Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CHARLES POCH INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CHARLES POCH INC. in W423 STATE RD 67, SAINT CLOUD, WI 53079 (NAICS 484110). OSHA activity number 338867831.

Watch Charles Poch INC. — free Get an email when a new federal OSHA severe-injury report for Charles Poch INC. is published. One employer, no account, unsubscribe in one click.
Establishment
CHARLES POCH INC.
Site address
W423 STATE RD 67
City
SAINT CLOUD
State
WI
ZIP
53079
Mailing
W423 STATE RD. 67, SAINT CLOUD, WI 53079
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
484110
Employees
26
Ownership type
A

10 citations on file for this inspection.

1910.215 A04

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1960.00 Reduced
29 CFR 1910.215(a)(4):     Grinding machinery was not used with work rest(s) to support offhand grinding work:    a)    Bench grinder in maintenance shop was not equipped with work rests.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $1960
  • — Z (S) $2800

1910.215 B09

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.215(b)(9):     Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel:    a)    Bench grinder in maintenance shop was not equipped with a tongue guard.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1960.00 Reduced
29 CFR 1910.1200(e)(1):     The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    a)    Employer did not develop a written Hazard Communication Program but had corrosive and extremely flammable chemicals on site, such as HC-175 Super Concentrated degreaser, HH-66 Thinner or HH-66 Vinyl Cement.    ABATEMENT CERTIFCATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $1960
  • — Z (S) $2800

1910.1200 F05 I

Serious Gravity 1 4 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(f)(5)(i):     The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein:    a)    Employer did not label waste oil containers or spray bottles with cleaning chemicals in the maintenance shop.      ABATEMENT CERTIFCATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 F05 II

Serious Gravity 1 4 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(f)(5)(ii):     The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings:    a)    Employer did not label waste oil containers or spray bottles with cleaning chemicals in the maintenance shop with the appropriate hazard warnings.      ABATEMENT CERTIFCATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 G08

Serious Gravity 5 3 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(g)(8):     The employer did not ensure that material safety data sheets were readily accessible to the employees in their work area during each work shift:    a)    Employer did not maintain a copy of material safety data sheets for each of the chemicals on site, such as degreaser, thinner, vinyl cement, oils or cleaners.    ABATEMENT CERTIFCATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(h)(1):     Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:    a)    Employer did not develop a training program for the employees but had corrosive and extremely flammable chemicals on site, such as HC-175 Degreaser, HH-66 Vinyl Cement or HH-66 Thinner.    ABATEMENT CERTIFCATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1904.31 A

Other-than-serious 1 instance 26 exposed
Issued
Abate by
Penalty
Initial $700.00 · Current $490.00 Reduced
29 CFR 1904.31(a):     Employer did not record on the OSHA 300 Log the recordable injuries and illnesses of all employees on your payroll:    a)    Employer did not fill out an OSHA 300 Log for 2012.      ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (O) $490
  • — Z (O) $700

1904.32 A04

Other-than-serious 1 instance 26 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1904.32(a)(4):     The employer did not post an OSHA 300A Form or equivalent by February 1 thru April 30:    a)    Employer did not develop an OSHA 300A for posting by February 1, 2013.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G02 I

Other-than-serious 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(2)(i):     Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    a)    Electrical cover missing from outlet on south wall of parts storage room and ceiling box in same room.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED