On , OSHA opened a complaint safety inspection of TORCO SUPPLY COMPANY, INC. in ROUTE 895 AND RIVER VIEW ROAD, BOWMANSTOWN, PA 18030 (NAICS 424690). OSHA activity number 338910599.
Where did this inspection happen?
- Establishment
- TORCO SUPPLY COMPANY, INC.
- Site address
- ROUTE 895 AND RIVER VIEW ROAD
- City
- BOWMANSTOWN
- State
- PA
- ZIP
- 18030
- Mailing
- 800 INTERCHANGE ROAD, LEHIGHTON, PA 18235
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424690
- Employees
- 4
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.132 A
- Issued
- Abate by
- Penalty
- Initial $2400.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered: a) Cylinder filling area; Employees were filling CO2 cylinders without the use of safety glasses, on or about 02/14/2013. Abatement Observed During Inspection - No Abatement Certification Required
Recent events (2)
- — I (S) $1200
- — Z (S) $2400
1910.215 A04
- Issued
- Abate by
- Penalty
- Initial $2400.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work: a) Bench grinder area; A Ryobi 8 inch bench grinder is used to clean metal and set screws weekly without a work rest, on or about 02/14/2013. Abatement Certification Required
Recent events (2)
- — I (S) $1200
- — Z (S) $2400
1910.215 B09
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a) Bench grinder area; A Ryobi 8 inch bench grinder is used to clean metal and set screws weekly without a tongue guard, on or about 02/14/2013. Abatement Certification Required
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B07 I
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment: a) Cylinder filling area; Several unused openings were not effectively closed on a 200 amp power panel, on or about 02/14/2013. Abatement Certification Required
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.303 G01
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $800.00 Reduced
General-duty citation text
29 CFR 1910.303(g)(1): Space about electric equipment. Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment: a) Cylinder filling area; The 200 amp power panel was blocked by battery chargers preventing employees from accessing the power panel if an emergency occurred, on or about 02/14/2013. Abatement Certification Required
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) Route 895 and Riverview Road Bowmanstown, PA 18030; A hazardous communication program was not developed, implemented or maintained for employees using compressed gases and other chemicals in the workplace, on or about 02/14/2013. Abatement Certification Required
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.132 D01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE): a) Route 895 and Riverview Road Bowmanstown, PA 18030; The employer has not verified a workplace hazard assessment for employees working in jobs with hazards that may be minimized by using personal protective equipment, on or about 02/14/2013. Abatement Certification Required
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 424690)
DEERFIELD BEACH, FL—2026-07-10
OXYGEN DEVELOPMENT
PAWTUCKET, RI—2026-07-08
SOLVENT DIRECT
HONOLULU, HI—2026-06-19
AIRGAS USA, LLC
BAYTOWN, TX—2026-06-16
SYNTHETIC OILS & LUBRICANTS OF TEXAS, INC.
INDIANAPOLIS, IN—2026-06-08
MINTEK RESOURCES / OMNI MATERIALS
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338910599.