OSHA Inspection: KNUST-SBO

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of KNUST-SBO in 8625 MEADOW CRAFT, HOUSTON, TX 77063 (NAICS 332710). OSHA activity number 338914336.

Watch Knust-Sbo — free Get an email when a new federal OSHA severe-injury report for Knust-Sbo is published. One employer, no account, unsubscribe in one click.
Establishment
KNUST-SBO
Site address
8625 MEADOW CRAFT
City
HOUSTON
State
TX
ZIP
77063
Mailing
8625 MEADOW CRAFT, HOUSTON, TX 77063
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
160
Ownership type
A

7 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2700.00 · Current $1620.00 Reduced
29 CFR 1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:    At the site where  employees perform maintenance and repair of machinery and equipment; the employer did not specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, exposing employees to potential caught between, electrical and amputation hazards.
Recent events (2)
  • — I (S) $1620
  • — Z (S) $2700

1910.212 A03 II

Serious Gravity 5 6 instances 12 exposed
Issued
Abate by
Penalty
Initial $4500.00 · Current $2700.00 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):     At the site in the processing area; employees operated lathes with the interlock systems bypassed, exposing employees to amputation hazards at:         a)    #50 Okuma Millac 852V, Serial #152495, 2011, Bldg. B-1 V         b)    #200 Morei Seiki MV 653/50, Serial #MV653H60503, Nov. 2008, Bldg. B-1, Vertical Mill CNC.         c)    #201 Okuma Millac 761v Mill, Serial#75459, Nov. 2008, Bldg. B-1, Vertical Mill CNC.         d)    #202 Okuma Millac 761v Mill, Serial #75460, Nov. 2008, Bldg..B-1, Vertical Mill CNC.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $4500

1910.219 C02 I

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2700.00 · Current $1620.00 Reduced
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting:    At the site, in building 3, the horizontal shaft of the Weiler E90 Vertical Mill CNC was not adequately guarded. This condition exposed employees to  struck by and caught between hazards.
Recent events (2)
  • — I (S) $1620
  • — Z (S) $2700

1910.303 B02

Serious Gravity 1 10 instances 20 exposed
Issued
Abate by
Penalty
Initial $2700.00 · Current $1620.00 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    a)    At the site in building 1 and various other locations, electrical receptacle  boxes are hanging from the ceiling which are not designed for that type of use, exposing employees electrical hazards     b)    At the site in building 3 there was a 30v receptacle wired into an electrical circuit box with flexible cable, exposing employees electrical hazards
Recent events (2)
  • — I (S) $1620
  • — Z (S) $2700

1910.305 B01 II

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $4500.00 · Current $2700.00 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:         a)    At the site in Building 1, a 240 V 3 phase electrical circuit breaker box on the north wall had an unused opening, exposing employees to electrical hazards.          c)    T building #1, an electrical cabinet was not effectively closed, exposing employees to electrical hazards.          b)    In Building 3, behind machine #69, a 480 volt circuit breaker panel, labeled as lights had an unused opening, exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $4500

1910.303 F02

Other-than-serious 3 instances 3 exposed
Issued
Abate by
Penalty
Initial $900.00 · Current $540.00 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:     At the site, in various buildings there were electrical circuit breaker boxes which were not labeled, partially labeled or labeling was illegible.      a)   Building 1,     b)   Building 3 in the saw room.     c)   Building 4.
Recent events (2)
  • — I (O) $540
  • — Z (O) $900

1910.305 G02 III

Other-than-serious 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $900.00 · Current $540.00 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:    At the jobsite in Building 1,  flex cord was missing strain relief, exposing employees to electrical hazards.
Recent events (2)
  • — I (O) $540
  • — Z (O) $900