Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SOVEREIGN DISTRIBUTORS, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of SOVEREIGN DISTRIBUTORS, INC. in 1939 OLNEY AVENUE SUITE 400, CHERRY HILL, NJ 08003 (NAICS 442210). OSHA activity number 338915747.

Watch Sovereign Distributors, INC. — free Get an email when a new federal OSHA severe-injury report for Sovereign Distributors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1939 OLNEY AVENUE SUITE 400
City
CHERRY HILL
State
NJ
ZIP
08003
Mailing
1939 OLNEY AVENUE, CHERRY HILL, NJ 08003
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
442210
Employees
120
Ownership type
A

5 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 40 exposed
Issued
Abate by
Penalty
Initial $6000.00 · Current $4500.00 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:Note:  Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard.   a) Avalon Dock Door #7: On or about 02/22/2013, at height greater than four (4) feet, employees disposing of refuse materials in the outdoor trash compactor were exposed to an open-sided platform that was not guarded by railings along all open sides.     NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • — I (S) $4500
  • — Z (S) $6000

1910.37 A03

Serious Gravity 1 2 instances 60 exposed
Issued
Abate by
Penalty
Initial $3000.00 · Current $2250.00 Reduced
29 CFR 1910.37(a)(3):   Exit route(s) were not kept free and unobstructed:  a) Warehouse Area-Exit Door #1: On or about 02/22/2013, an exit door was blocked by palletized flooring tiles and other flooring products which would prevent the safe egress of employees in the event of an emergency.  b) Warehouse Area-Exit Door #2: On or about 02/22/2013, an exit door was blocked by a powered ride along floor sweeper and palletized flooring material which would prevent the safe egress of employees in the event of an emergency.
Recent events (2)
  • — I (S) $2250
  • — Z (S) $3000

1910.176 A

Serious Gravity 5 1 instance 55 exposed
Issued
Abate by
Penalty
Initial $6000.00 · Current $4500.00 Reduced
29 CFR 1910.176(a):   Where mechanical handling equipment was used, sufficient safe clearances were not allowed for aisles, at loading docks, through doorways or wherever turns or passage had to be made:    a) Throughout the facility: On or about 02/22/2013, suffcient safe clearance for the manueverability of a Crown FC 4500 Series Cascade Sideshifter Forklift Truck to transport palletized flooring products was not provided in aisles: M075, 02G1, S059, 05D3, 07D1, 07P3, 08G3 and R031.
Recent events (2)
  • — I (S) $4500
  • — Z (S) $6000

1910.178 G02

Serious Gravity 1 1 instance 25 exposed
Issued
Abate by
Penalty
Initial $3000.00 · Current $2250.00 Reduced
29 CFR 1910.178(g)(2):   Battery charging apparatus for industrial trucks located in battery changing and charging installation was not protected from damage by trucks:   a) Warehouse Area near Panel Box B: On or about 02/22/2013, the charging cords on the Enforcer HF 163549 (M#: EH3-24-1000; S#: JF83771; 480 V, 13 Amps AC) and the Northeast Industrial Battery (M#: 3NE18-750; S#: 1219E4) industrial battery chargers  were damaged by forklift traffic exposing the employees to potential injury.
Recent events (2)
  • — I (S) $2250
  • — Z (S) $3000

1910.303 B02

Serious Gravity 1 5 instances 12 exposed
Issued
Abate by
Penalty
Initial $3000.00 · Current $2250.00 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    a) Warehouse Area- Panel Box B: On or about 02/22/2013, non-approved circuit breakers were used daily to operate the overhead lights and forklift truck battery chargers.   b) Warehouse Area-Panel Box #2: On or about 02/22/2013, non-approved circuit breakers were used daily to operate the overhead lights and forklift truck battery chargers.   c) Warehouse Area-Panel Box #5: On or about 02/22/2013, non-approved circuit breakers were used daily to operate the overhead lights, an outdoor trash compactor and forklift truck battery chargers.   d) Warehouse Area-Panel Box#4: On or about 02/22/2013, non-approved circuit breakers were used daily to operate the overhead lights, overhead heaters, forklift truck battery chargers and dock door motors for dock doors #5 & #6.   e) Warehouse Area- Staging Department: On or about 02/22/2013, non-approved circuit breakers were used daily to operate the overhead lights and forklift truck battery chargers.     NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • — I (S) $2250
  • — Z (S) $3000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338915747.