Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: DEWAINE KING CUSTOM CABINETS

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of DEWAINE KING CUSTOM CABINETS in 2552 HWY 69 S, LUMBERTON, TX 77657 (NAICS 337212). OSHA activity number 338916976.

Watch Dewaine King Custom Cabinets — free Get an email when a new federal OSHA severe-injury report for Dewaine King Custom Cabinets is published. One employer, no account, unsubscribe in one click.
Site address
2552 HWY 69 S
City
LUMBERTON
State
TX
ZIP
77657
Mailing
2552 HWY 69 S, LUMBERTON, TX 77657
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337212
Employees
2
Ownership type
A

5 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1910.23(c)(1):     Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:Note:  Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard.    The employer does not ensure that open-sided floor(s) or platform(s) 4 feet or more above the ground are guarded by railing on all open sides.  This violation was observed on or about February 7, 2013, on an unguarded overhead storage space above the Shop floor where an employee was exposed to a fall hazard of more than 4 feet when retrieving a fence for the table saw.     Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that open-sided floor(s) or platform(s) 4 feet or more above the adjacent floor or ground level are guarded by standard railings on all open sides.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.213 C01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1680.00 Reduced
29 CFR 1910.213(c)(1):     Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:    The employer does not guard the point of operation of machines whose operation exposes an employee to injury.  This violation was observed on or about February 7, 2013, on the Northeast side of the Shop where employees were exposed to a struck-by hazard when operating a table saw without a guard.    Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that guards are installed on all table saws to protect them from the point of operation.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.213 C02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.213(c)(2):     Hand-fed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator:    The employer does not guard the point of operation of machines whose operation exposes an employee to injury.  This violation was observed on or about February 7, 2013, on the Northeast side of the Shop where employees were exposed to a struck-by hazard when operating a table saw without a spreader.    Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that spreaders are installed on all table saws to protect them from hazards originating from the point of operation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.213 C03

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.213(c)(3):     Hand-fed ripsaw(s) did not have non kickback fingers or dogs designed to provide adequate holding power for all thicknesses of materials being cut:    The employer does not guard the point of operation of machines whose operation exposes an employee to injury.  This violation was observed on or about February 7, 2013, on the Northeast side of the Shop where employees were exposed to a struck-by hazard when operating a table saw without having a kickback device installed on it.    Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that kickback devices are installed on all table saws to protect them from hazards originating from the point of operation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B02 I

Serious Gravity 5 3 instances 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1910.305(b)(2)(i):     Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:  The employer does not provide a cover for each outlet box in completed electrical installations:      a.	This violation was observed on or about February 7, 2013 at the North wall of the Main Shop where employees were exposed to an electrical shock/burn hazard when operating the DeWalt Chop Saw whereas the electrical outlet box had no face plate.    b.	This violation was observed on or about February 7, on the North wall of the Main Shop near the ABC fire extinguisher where employees were exposed to an electrical shock/burn hazard when operating a DeWalt Chop Saw near an electrical outlet box which had no face plate on it.     c.	This violation was observed on or about February 7, on the North wall of the Main Shop where employees were exposed to an electrical shock /burn hazard when operating the DeWalt Chop Saw near a junction box which did not have a metal cover on it.    Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that all outlet boxes and junction boxes in completed installations have a face plate or cover on them.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338916976.