Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SHERIDAN ROAD LUMBER CO.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SHERIDAN ROAD LUMBER CO. in 6606 SHERIDAN RD., PEORIA, IL 61614 (NAICS 337110). OSHA activity number 338925530.

Watch Sheridan Road Lumber CO. — free Get an email when a new federal OSHA severe-injury report for Sheridan Road Lumber CO. is published. One employer, no account, unsubscribe in one click.
Site address
6606 SHERIDAN RD.
City
PEORIA
State
IL
ZIP
61614
Mailing
6606 SHERIDAN RD., PEORIA, IL 61614
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337110
Employees
12
Ownership type
A

15 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1000.00 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:     Employees were exposed to a fall hazard when retrieving foam in the far shed, because the platform was not equipped with a standard railing.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1600

1910.23 D01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1000.00 Reduced
29 CFR 1910.23(d)(1): Stairs having four or more risers were not equipped with standard stair railings or standard handrails as specified in paragraphs (d)(1)(i) through (v) of this section:    Employees were exposed to a fall hazard while using the stairs in the lumber area because both sides of the stairs were not equipped with a standard stair railing.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1600

1910.23 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1000.00 Reduced
29 CFR 1910.23(e)(1): Standard railing(s) did not consist of top rail, intermediate rail and/or posts and/or did not have a vertical height of 42 inches (106.7 cm) nominal from upper surface of top rail to floor, platform runway, or ramp level:    Employees were exposed to a fall hazard while using the catwalk to retrieve lumber because the platform was not equipped with a standard railing.   The railing did not include a midrail.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1600

1910.26 C03 III

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1000.00 Reduced
29 CFR 1910.26(c)(3)(iii): Ladders were used on surfaces which did not provide a secure footing:    Employees working in the far shed were exposed to a fall hazard when retrieving foam because the ladder did not have secure footing.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1600

1910.147 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1000.00 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    An employee changing the blade on the Delta Radial Saw was exposed to amputation hazards, because the employer did not develop, document and utilize an energy control procedure for the equipment.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1600

1910.147 C07 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees:   An employee changing blades on a Delta Radial Saw was exposed to amputation hazards, and the employer did not provide training to ensure employees had the knowledge and skills to control all hazardous energy during servicing operations.  This training would include training in the following:  a.      Recognition of applicable hazardous energy sources,  b.      Type and magnitude of energy available, and  c.       Methods and means necessary for energy isolation and control.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 L01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1000.00 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    Prior to allowing employees to use the powered industrial vehicles, the employer did not ensure that each operator had completed training, that included all of the truck and workplace related topics listed in the standard and completed an evaluation of the operators performance through practical exercise.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1600

1910.178 L06

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(l)(6):   The employer shall certify that each operator has been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation.   The employer did not document the required certification for each operator, which includes:   the operators name, date of the training, date of the evaluation and/or the name of the person conducting the evaluation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.213 P04

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $0.00 Reduced
29 CFR 1910.213(p)(4): Belt sanding machinery was not provided with a guard at each nip point where the sanding belt ran onto a pulley, to prevent the operator's hands or fingers from coming into contact with nip points:   An employee using the Craftsman Disc Sander/Grinder in the upstairs shop was exposed to caught in hazards because the sander was not protected with a guard at each nip point.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1600

1910.215 A02

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $1600.00 · Current $0.00 Reduced
29 CFR 1910.215(a)(2): Abrasive wheel(s) used on grinding machinery were not provided with safety guard(s) which covered the spindle end, nut, flange projections:    An employee was exposed to caught-in hazards while sharpening chisels because guards did not cover the spindle end and nut on the Craftsman Grinder in the upstairs shop.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1600

1910.215 B09

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.215(b)(9): Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel:   An employee was exposed to a struck-by hazards while sharpening chisels in the upstairs shop, because the Craftsman Grinder was not properly guarded with a tongue guard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.242 B

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $0.00 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:      An employee using compressed air for cleaning purposes was exposed to air embolisms and woodchips in the eyes because the air pressure was not reduced to less than 30 p.s.i.
Recent events (2)
  • — I (O) $0
  • — Z (S) $1200

1910.303 B02

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $0.00 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:      An employee was exposed to electrical shock when using the table saw in the upstairs shop.  The outlet box was attached to flexible conduit and not used in accordance with instructions included in the listing, labeling, or certification.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1600

1910.305 J02 IV

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $0.00 Reduced
29 CFR 1910.305(j)(2)(iv): A receptacle installed in a wet or damp location was not suitable for the location:    An employee was exposed to electrical shock when using the outside outlet in the lumber area, because the outlet box was not weather proof.
Recent events (2)
  • — I (O) $0
  • — Z (S) $1600

1904.29 A

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1904.29(a): The employer did not use an OSHA 300, 301 and 300A Form or equivalent.  On or about March 1, 2013, the employer forms used for recording injuries and illnesses were not an equivalent form for the calendar year 2013 and 2013.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338925530.