MARCY, NY —
OSHA Inspection: WALMART DISTRIBUTION CENTER 6038
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of WALMART DISTRIBUTION CENTER 6038 in 8827 OLD RIVER ROAD, MARCY, NY 13403 (NAICS 493110). OSHA activity number 338925605.
Where did this inspection happen?
- Establishment
- WALMART DISTRIBUTION CENTER 6038
- Site address
- 8827 OLD RIVER ROAD
- City
- MARCY
- State
- NY
- ZIP
- 13403
- Mailing
- 8827 OLD RIVER ROAD, MARCY, NY 13403
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493110
- Employees
- 750
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.22 B01
- Issued
- Abate by
- Penalty
- Initial $2550.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.22(b)(1): Aisles and passageways were not kept clear and in good repair, with no obstruction across or in aisles that could create a hazard: a) A Bldg., between Doors 101 and 102, on or about 3/8/13: There was an uneven surface at the seam of the concrete flooring, creating a tripping hazard. b) A Bldg., between Doors 97 and 98, on or about 3/8/13: There was an uneven surface at the seam of the concrete flooring, creating a tripping hazard. Abatement certification must be submitted for these items.
Recent events (3)
- — J (S) $0
- — C (S) $2550
- — Z (S) $2550
1910.23 A08
- Issued
- Abate by
- Penalty
- Initial $2550.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.23(a)(8): Every floor hole into which persons can accidentally walk were not guarded: a) B Bldg., Door #177, on or about 3/7/13: A floor hole measuring 5 1/2 inches X 5 1/2 inches at the left side of the dock plate and a 5 1/2 inches X 6 inch floor hole on the right side of the dock plate were not guarded. b) A Bldg., Door #135, on or about 3/8/13: A floor hole measuring 4 3/4 inches X 7 inches at the left side of the dock plate was not guarded. c) A Bldg., Door #115, on or about 3/8/13: A floor hole measuring 5 1/2 inches X 7 inches at the left side of the dock plate was not guarded. Abatement certification must be submitted for item c.
Recent events (3)
- — J (S) $0
- — C (S) $2550
- — Z (S) $2550
1910.151 C
- Issued
- Abate by
- Penalty
- Initial $3400.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a) B Bldg., Scrubber Bay, on or about 3/7/13: No eye wash was provided for employees dispensing DuBois Power Lift, a corrosive liquid. Abatement certification must be submitted for this item.
Recent events (3)
- — J (S) $0
- — C (S) $3400
- — Z (S) $3400
1910.176 B
- Issued
- Abate by
- Penalty
- Initial $3400.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.176(b): Material storage racks had damaged vertical supports and materials stored on storage racks were not stable and secure against sliding and collapse: a) C Bldg., F Module, on or about 3/7/13: Vertical upright on storage rack F256 was damaged. b) C Bldg., F Module, on or about 3/7/13: Vertical upright on storage rack F685 was damaged. c) B Bldg., B Module, on or about 3/7/13: Vertical upright on storage rack U0095 was damaged. Abatement certification must be submitted for instance c.
Recent events (3)
- — J (S) $0
- — C (S) $3400
- — Z (S) $3400
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $3400.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by rotating parts: a) B Bldg., Weld Shop, on or about 3/7/13: Rotating chuck on a Dayton drill press, Serial #88249, was not guarded.
Recent events (3)
- — J (S) $0
- — C (S) $3400
- — Z (S) $3400
1910.219 H01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.219(h)(1): Projecting key(s), setscrew(s), or other projections in revolving part(s) were not removed, made flush, or guarded by metal cover(s): a) C Bldg., D Module, on or about 3/7/13: Rotating shaft end with setscrew projections on a conveyor belt at Location D1764 was not guarded. b) C Bldg., B Module, on or about 3/7/13: Rotating shaft end with setscrew projections on a conveyor belt at Location B1501 was not guarded. c) B Bldg., U Module, on or about 3/7/13: Rotating shaft end with setscrew projections on a conveyor belt, north end of Location U0003 was not guarded. Abatement certification must be submitted for these items.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.303 B02
- Issued
- Abate by
- Penalty
- Initial $3400.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) C Bldg., Staple Stock QA, on or about 3/7/13: A relocatable power strip with a portable fan plugged in was not being used in accordance with the listing and labeling.
Recent events (3)
- — J (O) $0
- — C (S) $3400
- — Z (S) $3400
1910.304 G05
- Issued
- Abate by
- Penalty
- Initial $2550.00 · Current $2550.00
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a) A Bldg., Door 118, on or about 3/8/13: A Versa dock light was not grounded in that there was no ground continuity. b) A Bldg., Door 115, on or about 3/8/13: A Versa dock light was not grounded in that the ground pin was missing from the plug end.
Recent events (3)
- — J (S) $2550
- — C (S) $2550
- — Z (S) $2550
1910.303 B07 IV
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $2250.00
General-duty citation text
29 CFR 1910.303(b)(7)(iv): There were damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating: a) A Bldg., Door 132, on or about 3/8/13: Flexible conduit providing current to a red/blue light for the conveyor line was broken and unraveling, exposing conductors to damage. b) A Bldg., Door 106, on or about 3/8/13: Flexible conduit providing current to a light and fan unit was broken and unraveling, exposing conductors to damage. c) A Bldg., Door 105, on or about 3/8/13: Flexible conduit providing current to a fan switch was broken and unraveling, exposing conductors to damage. d) A Bldg., Door 98, on or about 3/8/13: Flexible conduit providing current to a Versa light and fan unit was broken and unraveling, exposing conductors to damage. e) A Bldg., Door 97, on or about 3/8/13: Flexible conduit providing current to a Versa light and fan unit and flexible conduit to a junction box were broken and unraveling, exposing conductors to damage.
Recent events (3)
- — J (S) $2250
- — C (S) $0
- — Z (S) $0
1910.305 G02 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: a) A Bldg., Door 140, on or about 3/8/13: Flexible cord providing current to the manual advance freight foot pedal override control for the sorter/loader was pulled loose at the plug fitting. b) A Bldg., Door 136, on or about 3/8/13: Flexible cord providing current to the manual advance freight foot pedal override control for the sorter/loader was pulled loose at the plug fitting. c) A Bldg., Door 118, on or about 3/8/13: Flexible cord providing current to a Versa dock light was pulled loose at the fitting next to the switch. d) A Bldg., Door 110, on or about 3/8/13: Flexible cord providing current to a Versa dock light was pulled loose at the fitting next to the switch. e) A Bldg., Door 102, on or about 3/8/13: Flexible cord providing current to a Versa dock light was pulled loose at the plug fitting. f) A Bldg., Door 102, on or about 3/8/13: Flexible cord providing current to a Versa dock light and fan unit was pulled loose at the fitting to the unit.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 493110)
PORTSMOUTH, VA—2026-07-15
DACS INC
WEST CHESTER, OH—2026-07-14
CRESCENT PARK CORPORATION
WEYMOUTH, MA—2026-07-14
SPEEDX
DUNDALK, MD—2026-07-09
WILLIAMS SCOTSMAN, INC.
ROCK HILL, SC—2026-07-08
77566 - WEST MARINE INC
More inspections in NY
MAYVILLE, NY—2026-07-16
MAYVILLE VILLAGE DPW
NEW HYDE PARK, NY—2026-07-16
NORTH HEMPSTEAD TN MICHAEL J TULLY PARK
CONESUS, NY—2026-07-16
CONESUS TN HIGHWAY DEPT
COMSTOCK, NY—2026-07-15
NYSDOCCS WASHINGTON CORRECTIONAL FACILITY
BALDWINSVILLE, NY—2026-07-15
LYSANDER TOWN HIGHWAY DEPARTMENT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338925605.