EAST LYNN, WV —
OSHA Inspection: CHOJNACKI CONSTRUCTION INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CHOJNACKI CONSTRUCTION INC. in INTERSECTION OF WOLF PEN BRANCH RD. AND BUCK FORK RD., EAST LYNN, WV 25512 (NAICS 237110). OSHA activity number 338930977.
Where did this inspection happen?
- Establishment
- CHOJNACKI CONSTRUCTION INC.
- Site address
- INTERSECTION OF WOLF PEN BRANCH RD. AND BUCK FORK RD.
- City
- EAST LYNN
- State
- WV
- ZIP
- 25512
- Mailing
- P.O. BOX 22, HAMLIN, WV 25523
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 12
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.95 A
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact. a. Intersection of Wolf Branch Road and Buck Fork Road: The operator of the Case 580 Super K 4x4 rubber tired backhoe (Serial # JJGO165942) was not utilizing the seatbelt while operating the backhoe as observed on 2-20-13. b. Intersection of Wolf Branch Road and Buck Fork Road: The operator of the Kobelco 135SR LC (Serial # YH0404460) Excavator was not utilizing the seatbelt while operating the excavator as observed on 2-20-13. c. Intersection of Turkey Camp Road and Buck Fork Road: The operator of the Case 580L 4x4 rubber tired backhoe (Serial # JJG0230684) was not utilizing the seatbelt while operating the backhoe as observed on 2-20-13. Abatement Certification Required for this Item.
Recent events (1)
- — Z (S) $1600
1926.600 A03 I
- Issued
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1926.600(a)(3)(i): Bulldozer and scraper blades, end-loader buckets, dump bodies, or similar equipment were not fully lowered or blocked when being repaired or when not in use: a. Intersection of Wolf Branch Road and Buck Fork Road. The bucket of the Kobelco 135SR LC (Serial # YH0404460) was left suspended approximately 3.5 feet while not in use as observed on 2-20-13.
Recent events (1)
- — Z (S) $1600
1926.602 A09 I
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $1200.00
General-duty citation text
29 CFR 1926.602(a)(9)(i): Bidirectional machine(s) were not equipped with an operable horn, distinguishable from the surrounding noise level, which could be operated as needed when the machine is moving in either direction: a. Intersection of Wolf Branch Road and Buck Fork Road: Case 580 Super K 4x4 rubber tired backhoe (Serial # JJG0165942) did not have an operable horn as determined on 2-20-13. b. Intersection of Turkey Camp Road and Buck Fork Road: Case 580 L 4x4 rubber tired backhoe (Serial # JJG0230684) did not have an operable horn as determined on 2-20-13. Abatement Certification Required for the Item.
Recent events (1)
- — Z (S) $1200
1926.602 A09 II
- Issued
- Abate by
- Penalty
- Initial $3200.00 · Current $3200.00
General-duty citation text
29 CFR 1926.602(a)(9)(ii): Earth moving or compacting equipment which had an obstructed view to the rear was operated in reverse gear; such equipment did not have in operation a reverse signal alarm distinguishable from the surrounding noise level or did an employee signaled that it is safe to do so. a. Intersection of Wolf Branch Road and Buck Fork Road: Case 580 Super K 4x4 rubber tired backhoe (Serial # JJG0165942) was being operated without an operable backup alarm as observed on 2-20-13. b. Tiger Fork Road: Kobelco 135SR LC excavator with vibratory plate attachment (Serial # YH03-02194) was being operated without an operable backup alarm as observed on 2-20-13. CHOJNACKI CONSTRUCTION COMPANY WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 1926.602(a)(9)(ii) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 311683254, CITATION NUMBER 1, ITEM NUMBER 4, ISSUED ON 04-08-2010. THIS ITEM BECAME FINAL ORDER ON 4-25-2010, AND ABATEMENT WAS CERTIFIED ON 4-25-2010 WITH RESPECT TO A WORKPLACE LOCATED AT COUNTY ROUTE 12 PRINTER ROAD SETH, WV 25181. Abatement Documentation Required for this Item.
Recent events (1)
- — Z (R) $3200
More inspections at CHOJNACKI CONSTRUCTION INC.
SETH, WV—2010-03-09 00:00:00
CHOJNACKI CONSTRUCTION INC.
View CHOJNACKI CONSTRUCTION INC.'s full OSHA safety record →
More inspections in this industry (NAICS 237110)
CHANDLER, AZ—2026-07-16
PREMIER UNDERGROUND CONSTRUCTION LLC
HIGHLAND PARK, IL—2026-07-16
UNITED PLUMBING AND DRAIN, INC.
CHICAGO, IL—2026-07-15
SUSTAINABLE SEWER & WATER INC.
LAKE FOREST, IL—2026-07-15
GREVERS CORPORATION DBA NORTH SHORE BORING
CHEYENNE, WY—2026-07-15
AZTEC CONSTRUCTION
More inspections in WV
CHARLESTON, WV—2026-07-15
ASTECH CORPORATION