Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JR PLASTERING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JR PLASTERING in 18401 W. LAKE HOUSTON, HUMBLE, TX 77346 (NAICS 238140). OSHA activity number 338933849.

Watch JR Plastering — free Get an email when a new federal OSHA severe-injury report for JR Plastering is published. One employer, no account, unsubscribe in one click.
Establishment
JR PLASTERING
Site address
18401 W. LAKE HOUSTON
City
HUMBLE
State
TX
ZIP
77346
Mailing
251 WOODSON DR, HOUSTON, TX 77060
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
3
Ownership type
A

5 citations on file for this inspection.

1926.451 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii)  The employer does not fully plank or deck between the front uprights and guardrail supports.  This violation was observed on or about March 4, 2013 on the southeast corner of the construction site where employees were exposed to an approximate 10 foot 3 inch fall hazard when performing masonry work without the working level being fully planked.  Pursuant to 29 C.F.R. 1903.19 within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that employees are protected from falling when exposed to falls  6 feet or more above a lower level.
Recent events (1)
  • — Z (S) $2800

1926.451 C02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames,  or uprights did not bear on base plates, mud sills or other adequate firm foundation:  The employer does not ensure that scaffold poles rested on a base plate.  This violation was observed on or about March 4, 2013 on the southeast corner of the construction site where employees were exposed to an approximate 10 foot 3 inch fall hazard when performing masonry work when one scaffold support pole did not rest on a base plate.   Pursuant to 29 C.F.R. 1903.19 within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that employees are protected from fall hazards when one scaffold leg did not rest upon a base plate.
Recent events (1)
  • — Z (S) $2000

1926.451 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used:   The employer does not ensure that a portable ladder, hook-on ladder, attachable ladder, stair tower (scaffold stairways/towers), stairway-type ladder (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was used with a scaffold platform more than 2 feet above a point of access.  This violation was observed on or about March 4, 2013 on the southeast corner of the construction site where employees were exposed to an approximate 10 foot  3 inch fall hazard when performing masonry work without using a safe means of access to and from the scaffold platform which was more than 2 feet above or below a point of access.   Pursuant to 29 C.F.R. 1903.19 within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that employees are protected from falling when exposed to falls 2 feet above or below a point of access on a scaffold.
Recent events (1)
  • — Z (S) $2000

1926.451 G01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:  The employer does not ensure that employees on scaffold more than 10 feet above a lower level are protected from falling to that lower level by fall protection.  This violation was observed on or about March 4, 2013 on the southeast corner of the construction site where employees were exposed to an approximate 10 foot 3 inch fall hazard when performing masonry work without fall protection.   Pursuant to 29 C.F.R. 1903.19 within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that employees are protected from fall hazards above 10 feet.
Recent events (1)
  • — Z (S) $2800

1926.416 E01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables shall not be used.  The employer does not ensure that worn or frayed electric cords are cables are used.  This violation was observed on or about March 4, 2013 on the southeast corner of the construction site where employees were using an worn extension cord attached to a GFCI.   Pursuant to 29 C.F.R. 1903.19 within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that employees are protected from worn or frayed electric cords..
Recent events (1)
  • — Z (O) $0

View JR PLASTERING's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338933849.