Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: HONOLULU WOOD TREATING, L.L.C.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HONOLULU WOOD TREATING, L.L.C. in 91-291 HANUA ST., KAPOLEI, HI 96707 (NAICS 423310). OSHA activity number 338943004.

Watch Honolulu Wood Treating, L.L.C. — free Get an email when a new federal OSHA severe-injury report for Honolulu Wood Treating, L.L.C. is published. One employer, no account, unsubscribe in one click.
Site address
91-291 HANUA ST.
City
KAPOLEI
State
HI
ZIP
96707
Mailing
91-291 HANUA ST., KAPOLEI, HI 96707
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423310
Employees
29
Ownership type
A

4 citations on file for this inspection.

1910.213 H03

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $3000.00 · Current $2250.00 Reduced
29 CFR 1910.213(h)(3):     Radial saw(s) were not provided with an adjustable stop to prevent the forward travel of the blade beyond the position necessary to complete the cut in repetitive operations:    The employer is failing to protect employees from laceration and amputation hazards by not properly ensuring the equipment is properly adjusted.  This is evidenced by the head of the saw extending past the edge of the table allowing employees the potential of contacting the lower portion of the blade.
Recent events (2)
  • — I (S) $2250
  • — Z (S) $3000

1910.215 A04

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $3000.00 · Current $0.00 Reduced
29 CFR 1910.215(a)(4):     Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:    The employer is failing to protect employees from laceration hazards by not properly guarding equipment.  The work rest on the bench grinder in the maintenance shop was not adjust adjacent to the wheel to the required 1/8 gap.  The gap measured at approximately .
Recent events (2)
  • — I (S) $0
  • — Z (S) $3000

1910.303 F02

Serious Gravity 5 3 instances 3 exposed
Issued
Penalty
Initial $3000.00 · Current $2250.00 Reduced
29 CFR 1910.303(f)(2):     Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:    The employer is failing to ensure that circuit breaker panel boxes are properly labeled for each circuit breaker in the box identifying that switch with the appropriate piece of equipment it serves.  Multiple panel boxes throughout the facility were not labeled as to what equipment in which they were dedicated.
Recent events (2)
  • — I (S) $2250
  • — Z (S) $3000

1910.305 B01 II

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $3750.00 · Current $2813.00 Reduced
29 CFR 1910.305(b)(1)(ii):     Unused openings in boxes, cabinets, or fittings were not effectively closed:    The employer is failing to ensure that employees are protected from electrical hazards.  Employees working near or on the circuit breaker panel box in this area are exposed to live parts due missing breakers creating openings in this box.
Recent events (2)
  • — I (S) $2812.5
  • — Z (S) $3750

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338943004.