Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: BUTLER AND COMPANY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BUTLER AND COMPANY, INC. in 205 BUTLER CIRCLE SW P.O. BOX 570, VERNON, AL 35592 (NAICS 484121). OSHA activity number 338944440.

Watch Butler AND Company, INC. — free Get an email when a new federal OSHA severe-injury report for Butler AND Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
205 BUTLER CIRCLE SW P.O. BOX 570
City
VERNON
State
AL
ZIP
35592
Mailing
205 BUTLER CIRCLE SW P.O. BOX 570, VERNON, AL 35592
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
484121
Employees
52
Ownership type
A

4 citations on file for this inspection.

1910.215 A04

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3000.00 · Current $1800.00 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one-eighth inch:      (a) On or about March 7, 2013 - 205 Butler Circle SW, Vernon, AL, Bay 2, an electric grinder Model# JBG-6A, Stock# 577101, S/N# 6425996, was not adjusted to one-eighth inch of the grinding wheel.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $3000

1910.215 B09

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one-fourth inch:      (a) On or about March 7, 2013 - 205 Butler Circle SW, Vernon, AL, Bay 2, an electric grinder Model# JBG-6A, Stock# 577101, S/N# 6425996, was not adjusted to one-fourth inch of the grinding wheel.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $2625.00 · Current $1575.00 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:      (a) On or about March 7, 2013 - 205 Butler Circle SW, Vernon, AL, Bay 1, unused openings in a circuit breaker panel were not effectively closed.     (b) On or about March 7, 2013 - 205 Butler Circle SW, Vernon, AL, Bay 1, unused openings in a circuit breaker panel were not effectively closed.
Recent events (2)
  • — I (S) $1575
  • — Z (S) $2625

1910.134 C02 I

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:      (a) On or about March 7, 2013 - 205 Butler Circle SW, Vernon, AL, employees wearing SAS N95 respirators had not been provided a copy of Appendix D.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338944440.