MORTON GROVE, IL —
OSHA Inspection: EXPERTIZE MASONRY, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of EXPERTIZE MASONRY, INC. in 8655 NARRAGANSETT AVE., MORTON GROVE, IL 60053 (NAICS 238140). OSHA activity number 338946270.
Where did this inspection happen?
- Establishment
- EXPERTIZE MASONRY, INC.
- Site address
- 8655 NARRAGANSETT AVE.
- City
- MORTON GROVE
- State
- IL
- ZIP
- 60053
- Mailing
- 6 WONDER WAY, LAKE IN THE HILLS, IL 60707
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 2
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.451 C01
- Issued
- Abate by
- Penalty
- Initial $2200.00 · Current $2200.00
General-duty citation text
29 CFR 1926.451(c)(1): Supported scaffold(s) with a height to base width (including outrigger supports) ratio greater than four to one (4:1) was not restrained from tipping by guying, tying, bracing, or equivalent means: a) Subcontractor's employees were exposed to fall hazards of approximately 30 feet while working on a frame scaffold which was not restrained from toppling by any means. The scaffold was approximately 30 feet high by 5 feet wide. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (3)
- — A (S) $2200
- — I (S) $1320
- — Z (S) $2200
1926.451 G01
- Issued
- Abate by
- Penalty
- Initial $3080.00 · Current $3080.00
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level. a) Subcontractor's employees were exposed to the hazard of falling while performing masonry work from tubular welded frame scaffold platform elevated approximately 30 feet above the ground. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
- — A (S) $3080
- — I (S) $1850
- — Z (S) $3080
More inspections at EXPERTIZE MASONRY, INC.
CHICAGO, IL—2009-06-12 00:00:00
EXPERTIZE MASONRY, INC.
CHICAGO, IL—2009-03-19 00:00:00
EXPERTIZE MASONRY, INC.
RIVER GROVE, IL—2006-08-10 00:00:00
EXPERTIZE MASONRY, INC.
View EXPERTIZE MASONRY, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238140)
MARIANNA, FL—2026-07-13
PRIMETIME MOBILE MASONRY LLC
LOMPOC, CA—2026-07-10
UNKNOWN EMPLOYER
FREEHOLD, NJ—2026-07-10
CRAIG'S MASONRY & HARDSCAPE LLC
CINCINNATI, OH—2026-07-09
ALL AMERICAN CONCRETE LLC
NEW YORK, NY—2026-07-08
JEY CONSTRUCTIONS WORKS CORP
More inspections in IL
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
GRANITE CITY, IL—2026-07-13
UNITED STATES STEEL CORPORATION
DECATUR, IL—2026-07-10
TILLAMOOK ILLINOIS, LLC
NEW LENOX, IL—2026-07-10
A.D GENERAL CONSTRUCTION LLC
LOCKPORT, IL—2026-07-09
ROBERTO GOMEZ DBA ROBERTO GOMEZ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338946270.