OSHA Inspection: WEST CONTINENTAL ENERGY SERVICES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WEST CONTINENTAL ENERGY SERVICES, INC. in 15802 INDUSTRIAL DRIVE, INDEPENDENCE, MO 64058 (NAICS 237120). OSHA activity number 338950686.

Watch West Continental Energy Services, INC. — free Get an email when a new federal OSHA severe-injury report for West Continental Energy Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
15802 INDUSTRIAL DRIVE
City
INDEPENDENCE
State
MO
ZIP
64058
Mailing
15802 INDUSTRIAL DRIVE, INDEPENDENCE, MO 64058
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237120
Employees
3
Ownership type
A

6 citations on file for this inspection.

1910.23 D01

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $1000.00 Reduced
29 CFR 1910.23(d)(1):  Every flight of stairs having four or more risers was not equipped with standard stair railings or standard handrails as specified in paragraphs (d)(1)(i) through (v) of this section:      (a) On or about January 23, 2013, a stairway having four or more risers and used to access the upper offices of the facility was not equipped with a standard handrail.      Abatement certification is required for this item.  Use the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET for this purpose.
Recent events (2)
  • — I (O) $1000
  • — Z (S) $2100

1910.23 E01

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $0.00 Reduced
29 CFR 1910.23(e)(1):  Standard railing(s) did not consist of top rail, intermediate rail and/or posts and/or did not have a vertical height of 42 inches (106.7 cm) nominal from upper surface of top rail to floor, platform runway, or ramp level:      (a) On or about January 23, 2013, the railing on a stairway receiving platform used for access to the upper offices lacked an intermediate (mid) rail.      Abatement certification is required for this item.  Use the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET for this purpose.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2100

1910.157 C01

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $500.00 Reduced
29 CFR 1910.157(c)(1):  Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:      (a) On or about January 23, 2013, none of the fire extinguishers in the first floor shop area were mounted, some were in unidentified areas, and at least one fire extinguisher identification sign was in an area where there was no fire extinguisher.      Abatement certification is required for this item.  Use the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET for this purpose.
Recent events (2)
  • — I (O) $500
  • — Z (S) $2100

1910.305 B01 II

Serious Gravity 5 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1000.00 Reduced
29 CFR 1910.305(b)(1)(ii):  Unused openings in boxes, cabinets, or fittings were not effectively closed:      (a) On or about January 23, 2013, two energized electrical outlet boxes had knockouts missing.  One outlet box was located in the southwest corner of the shop, the other in the northeast corner.      Abatement certification is required for this item.  Use the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET for this purpose.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2800

1910.305 G02 III

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $1000.00 Reduced
29 CFR 1910.305(g)(2)(iii):  Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:        (a) On or about January 24, 2013, a 220V flexible cable had pulled loose from its attachment point to a portable outlet box leaving the cable attached to the device by its internal conductors.      Abatement certification is required for this item.  Use the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET for this purpose.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $4900

1910.1200 F06 I

Deleted Serious Gravity 1 3 instances 4 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $0.00 Reduced
29 CFR 1910.1200(f)(6)(i):  Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information required by 29 CFR 1910.1200(f)(1)(i) through 29 CFR 1910.1200(f)(1)(v):      (a) On or about January 24, 2013, several 55 gallon drums and smaller containers of hazardous materials were present in the facility and unmarked as to contents or hazards.      Abatement certification is required for this item.  Use the CERTIFICATION OF CORRECIVE ACTION WORKSHEET for this purpose.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2100

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338950686.