ONEONTA, NY —
OSHA Inspection: FOXMAR, INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of FOXMAR, INC in 21 HOMER FOLKS ROAD, ONEONTA, NY 13820 (NAICS 611513). OSHA activity number 338954787.
Where did this inspection happen?
- Establishment
- FOXMAR, INC
- Site address
- 21 HOMER FOLKS ROAD
- City
- ONEONTA
- State
- NY
- ZIP
- 13820
- Mailing
- 2422 AIRWAY DRIVE, BOWLING GREEN, KY 42103
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 611513
- Employees
- 750
- Ownership type
- A
Citations
14 citations on file for this inspection.
1910.242 B
- Issued
- Abate by
- Penalty
- Initial $5000.00 · Current $3500.00 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) Oneonta Job Corps Maintenance Shop - On or about 9 May, 2013 - Employees were using compressed air that was at 125 p.s.i. to clean off tables and equipment.
Recent events (2)
- — I (S) $3500
- — Z (S) $5000
1910.304 G05
- Issued
- Abate by
- Penalty
- Initial $4000.00 · Current $2800.00 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a) 21 Homer Folks Road Facility Maintenance Trade Shop - On or about 9 May, 2013 - Employees were using a table saw that was missing the ground prong. b) 21 Homer Folks Road Cafeteria Kitchen - On or about 9 May, 2013 - Employees were using an extension cord to power a floor fan that was missing the ground prong.
Recent events (2)
- — I (S) $2800
- — Z (S) $4000
1910.334 A02 I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): a) 21 Homer Folks Road Cafeteria Kitchen - On or about 9 May, 2013 - Employees were using an extension cord to power a floor fan that was not visually inspected before use and had external defects.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B07 I
- Issued
- Penalty
- Initial $5000.00 · Current $3500.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment: a) 21 Homer Folks Road Maintenance Shop Restroom - On or about 9 May, 2013 - Employees were exposed to live electrical conductors in a light fixture over the sink that was not equipped with a housing to effectively afford protection to employees while operating the light switch that is connected to the light housing.
Recent events (2)
- — I (S) $3500
- — Z (S) $5000
1910.305 B02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: a) 21 Homer Folks Road Student Government Advisor Office - On or about 9 May, 2013 - Employees were using an outlet that did not have a faceplate installed. b) 21 Homer Folks Road Lisa Hall Room - On or about 9 May, 2013 - Employees were using an outlet that did not have a faceplate installed.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B01 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) 21 Homer Folks Road Food Services Managers Office - On or about 9 May, 2013 - Employees were exposed to live electrical conductors in an electrical panel that was missing a cover where a circuit breaker was previously installed. b) 21 Homer Folks Road Auto Body Storage Foyer - On or about 9 May, 2013 - Employees were exposed to live electrical conductors in a outlet/light switch box missing knockouts for conduit.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 D02
- Issued
- Abate by
- Penalty
- Initial $5000.00 · Current $3500.00 Reduced
General-duty citation text
29 CFR 1910.305(d)(2): Panelboards were not mounted in cabinets, cutout boxes, or enclosures designed for the purpose and/or were not dead front: a) 21 Homer Folks Road Smart Meter Classroom - On or about 13 March, 2013 - Employees were exposed to live electrical conductors when a panelboard was not equipped with a dead front.
Recent events (2)
- — I (S) $3500
- — Z (S) $5000
1910.22 B01
- Issued
- Abate by
- Penalty
- Initial $3000.00 · Current $2100.00 Reduced
General-duty citation text
29 CFR 1910.22(b)(1): Aisles and passageways were not kept clear and in good repair, with no obstruction across or in aisles that could create a hazard. a) Oneonta Job Corps Maintenance Shop Restroom - On or about 9 May, 2013 - Employees were using the restroom with the passageway that was obstructed creating a trip hazard.
Recent events (2)
- — I (S) $2100
- — Z (S) $3000
1910.36 D01
- Issued
- Abate by
- Penalty
- Initial $4000.00 · Current $2800.00 Reduced
General-duty citation text
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge: a) Oneonta Job Corps Dry Goods Storage - On or about 9 May, 2013 - Employees were working in a building with an identified emergency exit door that was not able to be open from the inside at all times.
Recent events (2)
- — I (S) $2800
- — Z (S) $4000
1910.179 B05
- Issued
- Abate by
- Penalty
- Initial $4000.00 · Current $2800.00 Reduced
General-duty citation text
29 CFR 1910.179(b)(5): The rated load of crane(s) was not plainly marked on each side of the crane: a) Oneonta Job Corps Automotive Mechanics Shop - On or about 9 May, 2013 - Employees were using an overhead crane that did not have the rated load of the crane clearly marked on each side of the crane.
Recent events (2)
- — I (S) $2800
- — Z (S) $4000
1910.179 J01 II B
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.179(j)(1)(ii)(b): A complete periodic inspection of crane(s) had not been conducted in the past 12 months: a) Oneonta Job Corps Automotive Mechanics Shop - On or about 9 May, 2013 - Employees were using an overhead crane that had not been inspected in the past 12 months.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.213 B03
- Issued
- Abate by
- Penalty
- Initial $3000.00 · Current $2100.00 Reduced
General-duty citation text
29 CFR 1910.213(b)(3): Provisions were not made to prevent woodworking machine(s) from automatically restarting upon restoration of power after power failure: a) Oneonta Job Corps Maintenance Shop - On or about 13 March, 2013 - Employees were using a table saw that was not equipped with provisions to prevent it from automatically restarting upon restoration of power after a power failure.
Recent events (2)
- — I (S) $2100
- — Z (S) $3000
1910.303 B02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) 21 Homer Folks Road Purchasing Office - On or about 9 May, 2013 - Employees were using a relocatable power tap that was powering another relocatable power tap to increase the number of power outlets available.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 B02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) 21 Homer Folks Road Recreation Center Office - On or about 9 May, 2013 - Employees were using a relocatable power tap that was powered by an extension cord and used to supply power to a refrigerator and microwave oven.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 611513)
IRVING, TX—2025-03-19
TULSA WELDING SCHOOL/DALLAS CAMPUS, INC.
SHELTON, WA—2025-01-13
WA317984078 - AEROSPACE MACHINISTS JOINT TRAINING COMMITTEE
SOUTH BURLINGTON, VT—2024-09-25 00:00:00
ADVANCED WELDING INSTITUTE, LLC
PORTLAND, OR—2024-08-23 00:00:00
317737580 - IMPACT NW
HILLSBORO, OR—2024-08-23 00:00:00
317737589 - IMPACT NW
More inspections in NY
MAYVILLE, NY—2026-07-16
MAYVILLE VILLAGE DPW
NEW HYDE PARK, NY—2026-07-16
NORTH HEMPSTEAD TN MICHAEL J TULLY PARK
CONESUS, NY—2026-07-16
CONESUS TN HIGHWAY DEPT
COMSTOCK, NY—2026-07-15
NYSDOCCS WASHINGTON CORRECTIONAL FACILITY
BALDWINSVILLE, NY—2026-07-15
LYSANDER TOWN HIGHWAY DEPARTMENT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338954787.