NORFOLK, VA —
OSHA Inspection: SURFACE PREPARATION AND COATINGS CORP
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of SURFACE PREPARATION AND COATINGS CORP in 3412 STRATHMORE AVE., NORFOLK, VA 23504 (NAICS 336611). OSHA activity number 338956592.
Where did this inspection happen?
- Establishment
- SURFACE PREPARATION AND COATINGS CORP
- Site address
- 3412 STRATHMORE AVE.
- City
- NORFOLK
- State
- VA
- ZIP
- 23504
- Mailing
- 3412 STRATHMORE AVE., NORFOLK, VA 23504
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336611
- Employees
- 20
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.242 B
- Issued
- Abate by
- Penalty
- Initial $1020.00 · Current $1020.00
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a.) Surface Preparation and Coatings, Shop: On or about 03/14/13, employees were using compressed air to clean tools and parts at greater than 100 p.s.i., creating a physical hazard.
Recent events (1)
- — Z (S) $1020
1910.303 G02 I
- Issued
- Abate by
- Penalty
- Initial $1360.00 · Current $1360.00
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): a.) Surface Preparation and Coatings Corp, Shop Area: On or about 03/14/13, openings in a 120 volt panel box exposed live parts of electrical equipment, creating a contact with electrical current or arc flash hazard.
Recent events (1)
- — Z (S) $1360
1915.173 E
- Issued
- Abate by
- Penalty
- Initial $1020.00 · Current $1020.00
General-duty citation text
29 CFR 1915.173(e): Containers of 55 gallons or more capacity containing flammable or toxic liquid were not surrounded by dikes or pans that enclose a volume equal to at least 35 percent of the total volume of the containers. a.) Surface Preparation and Coatings Corp., Yard: On or about 03/14/13, 4-55 gallon drums of flammable paint thinner did not have spill containment, creating a contact with flammable liquids fire hazard.
Recent events (1)
- — Z (S) $1020
1910.134 F02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using a tight-fitting facepiece respirator were not annually fit tested: a.) Surface Preparation and Coatings Corp., Shop: On or about 03/14/13, employees required to wear tight-fitting negative pressure respirators while painting were not fit tested annually, creating a contact with toxic substance hazard.
Recent events (1)
- — Z (O) $0
1910.178 L06
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): a.) Surface Preparation and Coatings Corp., Shop: On or about 03/14/13, an employee was not certified to operate the Hyster 50 powered industrial truck.
Recent events (1)
- — Z (O) $0
1910.304 G05
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a.) Surface Preparation and Coatings Corp., Shop: On or about 03/14/13, three 120 volt outlets available for use had an open ground, creating a contact with electrical current hazard.
Recent events (1)
- — Z (O) $0
1910.303 F02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: a.) Surface Preparation and Coatings Corp., Shop: On or about 03/14/13, the 120 volt panel box was not labeled to indicate what each breaker serviced, creating a contact with electrical current hazard.
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 336611)
AMELIA, LA—2026-07-10
CONRAD SHIPYARD, LLC
PORTSMOUTH, VA—2026-07-09
PALFINGER MARINE USA INC.
STUART, FL—2026-07-07
APPLIED CONCEPTS UNLEASHED, INC.
VANCOUVER, WA—2026-07-02
WA317991919 - JT MARINE INC
STUART, FL—2026-07-02
OCEAN MASTERS MARINE
More inspections in VA
WARSAW, VA—2026-07-10
CARR'S TIRE SERVICE
CHESAPEAKE, VA—2026-07-10
A&W CONTRACTORS, INC.
ROANOKE, VA—2026-07-10
NORTHWEST ACE HARDWARE
LYNCHBURG, VA—2026-07-10
RIVERFRONT HOSPITALITY LLC
CLOVERDALE, VA—2026-07-10
CUMMINS SALES AND SERVICE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338956592.