SYRACUSE, NY —
OSHA Inspection: GYPTECH SYSTEMS, INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of GYPTECH SYSTEMS, INC. in 301 PROSPECT AVENUE, SYRACUSE, NY 13203 (NAICS 238310). OSHA activity number 338958069.
Where did this inspection happen?
- Establishment
- GYPTECH SYSTEMS, INC.
- Site address
- 301 PROSPECT AVENUE
- City
- SYRACUSE
- State
- NY
- ZIP
- 13203
- Mailing
- PO BOX 2700, LIVERPOOL, NY 13089
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238310
- Employees
- 5
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.451 E01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1680.00 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. a) On or about 3/13/2013, N5 Elevation: No safe access was provided for the rolling scaffold being used to apply fire proofing. Abatement certification is required for this item.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1926.451 F03
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1680.00 Reduced
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: a) On or about 3/13/2013, N5 Elevation: No daily inspections were being performed on the rolling scaffold being used to apply fire proofing. Abatement certification is required for this item.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1926.451 F04
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1680.00 Reduced
General-duty citation text
29 CFR 1926.451(f)(4): Part(s) of a scaffold that were damaged or weakened, such that the scaffold's strength was less than that required by paragraph (a) of this section, were not immediately repaired, replaced, braced to meet those provisions, nor removed from service until repaired: a) On or about 3/13/2013, N5 Elevation: A caster locking mechanism was broken on the rolling scaffold being used to apply fire proofing. Abatement certification is required for this item.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1926.452 W02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.452(w)(2): Scaffold casters and wheels were not locked with positive wheel and/or wheel and swivel locks, or equivalent means, to prevent movement of the scaffold while the scaffold was used in a stationary manner: a) On or about 3/13/2013, N5 Elevation: Casters were not locked while an employee was applying fireproofing from rolling scaffold. Abatement certification is required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G01 VII
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1680.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: a) On or about 3/13/2013, N5 Elevation: A midrail was missing on one end of the rolling scaffold being used to apply fire proofing. Abatement certification is required for this item.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1926.452 W06 I
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1680.00 Reduced
General-duty citation text
29 CFR 1926.452(w)(6)(i): Employee(s) were allowed to ride on scaffolds when the surface on which the scaffold was moved was not within 3 degrees of level, and/or not free of pits, holes, and obstructions: a) On or about 3/13/2013, N5 Elevation: An employee was riding on a mobile scaffold used to apply fire proofing while near floor openings. Abatement certification is required for this item.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1926.452 W06 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.452(w)(6)(ii): The height to base width ratio of the scaffold during movement is two to one or less: a) On or about 3/13/2013, N5 Elevation: A mobile scaffold was in use with a width to height ratio of 2.7 while applying fire proofing. Abatement certification is required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238310)
BANNOCKBURN, IL—2026-07-16
BUILDER SERVICES GROUP, INC. DBA CJ INSULATION
NAMPA, ID—2026-07-15
INTERIOR SYSTEMS, INC.
BRIDGEPORT, WV—2026-07-14
EASLEY & RIVERS, INC.
ELLETTSVILLE, IN—2026-07-13
ENVIRO HEAT, LLC
ELLETTSVILLE, IN—2026-07-13
RWS INSULATION SERVICES, LLC
More inspections in NY
MAYVILLE, NY—2026-07-16
MAYVILLE VILLAGE DPW
NEW HYDE PARK, NY—2026-07-16
NORTH HEMPSTEAD TN MICHAEL J TULLY PARK
CONESUS, NY—2026-07-16
CONESUS TN HIGHWAY DEPT
COMSTOCK, NY—2026-07-15
NYSDOCCS WASHINGTON CORRECTIONAL FACILITY
BALDWINSVILLE, NY—2026-07-15
LYSANDER TOWN HIGHWAY DEPARTMENT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338958069.