Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: ENVIRO-TECH INDUSTRIES, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ENVIRO-TECH INDUSTRIES, LLC in 11624 W PRESIDENT DR, BOISE, ID 83713 (NAICS 332710). OSHA activity number 338958564.

Watch Enviro-Tech Industries, LLC — free Get an email when a new federal OSHA severe-injury report for Enviro-Tech Industries, LLC is published. One employer, no account, unsubscribe in one click.
Site address
11624 W PRESIDENT DR
City
BOISE
State
ID
ZIP
83713
Mailing
11624 W PRESIDENT DR, BOISE, ID 83713
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
34
Ownership type
A

4 citations on file for this inspection.

1910.303 B02

Serious Gravity 1 2 instances 6 exposed
Issued
Abate by
Penalty
Initial $1785.00 · Current $1250.00 Reduced
29 CFR 1910.303(b)(2):     Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.    (a) Rear shop area: on 03/14/2013 and at times prior thereto, a relocatable power tap (RPT) UL listed for household use was used to supply power to a 9.6 ampere vacuum and a 3.5 amp palm sander which exceeds 80% of the RPT ampere rating.    (b) Rear shop area: on 3/14/2013 and at times prior thereto, two RPTs were connected to temporary electrical power cords rather than directly to permanent power as required by the listing and labeling.    Note: Abatement certification IS required for this item.
Recent events (2)
  • — I (S) $1249.5
  • — Z (S) $1785

1910.305 G01 IV

Serious Gravity 1 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv):     Flexible cords and/or cables were used for purposes prohibited by paragraphs (A) and (C) of 29 CFR 1910.305(g)(1)(iv):    (a) Rear shop area: on 03/14/2013 and at times prior thereto, flexible cords were used to provide permanent power to a shop vacuum, battery chargers, and a palm sander.     (b)  Rear shop area: on 03/14/2013 and at times prior thereto, a flexible cord was routed through a loosened access panel to provide permanent lighting inside the protective case of a Hyundai-Kia Vertical Milling Machine, Model VX650.    NOTE:  Abatement certification IS required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(2)(iii):     Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:    (a) Rear shop area: on 03/14/2013 and at times prior thereto, the case of a Newport model 99J1 relocatable power tap cord fitting was damaged to the point that strain relief was not provided.    NOTE: Abatement certification IS required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1904.40 A

Other-than-serious 1 instance 32 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1904.40(a):     The employer did not provide an authorized government representative the records within the four business hours.    (a) Establishment: On 3/14/2013 and at times prior thereto, the employer failed to provide copies of the injury and illness records to an authorized representative within the allowable time.    NOTE: Abatement certification IS NOT required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338958564.