KEENE, NH —
OSHA Inspection: TIDLAND CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TIDLAND CORPORATION in 11 BRADCO ST, KEENE, NH 03431 (NAICS 333291). OSHA activity number 338965627.
Where did this inspection happen?
- Establishment
- TIDLAND CORPORATION
- Site address
- 11 BRADCO ST
- City
- KEENE
- State
- NH
- ZIP
- 03431
- Mailing
- 11 BRADCO STREET, KEENE, NH 03431
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333291
- Employees
- 60
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $2625.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Instance a. Site - On or about March 18, 2013, the gray single-wheel bench grinder's spindle end, nut and flange was not guarded. Instance b. Site - On or about March 18, 2013, the unused portion of the horizontal blade on the W.F Wells & Sons (model L) 9 inch metal band saw was not guarded. Instance c. Site - On or about March 18, 2013, the gray Craftsman (BS) bandsaw blade was not guarded.
Recent events (2)
- — I (S) $2625
- — Z (S) $3500
1910.215 A04
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $2625.00 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: a. Site - The Baldor (model grinder-buffer S/N G7-390-385) bench grinder tool rest was adjusted to 1.5 inches.
Recent events (2)
- — I (S) $2625
- — Z (S) $3500
1910.215 B09
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $2625.00 Reduced
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a. Site - On or about March 18, 2013, tongue guarding was not provided on the Baldor (model grinder-buffer S/N G7-390-385) bench grinder.
Recent events (2)
- — I (S) $2625
- — Z (S) $3500
1910.303 B01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2100.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees: a. Site - On or about March 18, 2013, the Ace Hardware multiple electrical outlet device in use was not designed for commercial or industrial use.
Recent events (2)
- — I (S) $2100
- — Z (S) $2800
1910.242 B
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $2625.00 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a. Site - Compressed air utilized for cleaning purposes at employees workstations was at 100 PSI.
Recent events (2)
- — I (S) $2625
- — Z (S) $3500
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $48400.00 · Current $36300.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips: Instance a. Hwacheon Machinery Co. LTD (Model HL-460 S/N 228320) Lathe machine - Employees operating the lathe were not protected from flying chips and rotating parts. Instance b. Lathe Polisher machine - Employees operating the lathe were not protected from flying chips and rotating parts. Instance c. Yamazaki metals Lathe (L7) - Employees operating the lathe were not protected from rotating parts. Instance d. Whacheon Machinery Co. LTD (model 520 2000) metals Lathe - Employees operating the lathe were not protected from rotating parts. Instance e. Moriseiki metal (model MS-1250) (L4) metals Lathe - Employees operating the lathe were not protected from rotating parts. Instance f. Hwhacheon Machinery Co. LTD (HL 18X59 L-10) metals Lathe - Employees operating the lathe were not protected from rotating parts. Instance g. Regal LeBlond (U-54) metals Lathe - Employees operating the lathe were not protected from rotating parts. Instance h. Whacheon 32120 (S/N 5H404) (L-15) metals Lathe - Employees operating the lathe were not protected from rotating parts. Instance i. Poreba (42-480) (L12) metals Lathe - Employees operating the lathe were not protected from rotating parts. Delete Instance "J" Instance k. Whacheon Machinery Co. LTD (model 435-1500 S/N 8803-07) metals Lathe - Employees operating the lathe were not protected from rotating parts.
Recent events (2)
- — I (W) $36300
- — Z (W) $48400
1910.303 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: Instance a. Site - On or about March 18, 2013, the electrical panel box in the maintenance department was blocked and not made accessible during emergency events. Instance b. Site - On or about March 18, 2013, the electrical disconnect (L-16) was blocked and not made accessible during emergency events.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.157 C01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(c)(1): Employer did not provide portable fire extinguishers which were mounted, located, and identified, so as to be readily accessible for emplooyee use: a. Site - On or about March 18, 2013, the fire extinguisher was blocked by storage and not made available in case of fire.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at TIDLAND CORPORATION
CAMAS, WA—2011-10-17 00:00:00
TIDLAND CORPORATION
CAMAS, WA—2010-05-27 00:00:00
TIDLAND CORPORATION
View TIDLAND CORPORATION's full OSHA safety record →
More inspections in this industry (NAICS 333291)
GASTONIA, NC—2024-08-12 00:00:00
157258 - PETTY MACHINE COMPANY, INCORPORATED
SPOKANE, WA—2024-02-27 00:00:00
WA317978778 - ALLIANCE MACHINE SYSTEMS INTERNATIONAL LLC
SPOKANE, WA—2024-02-27 00:00:00
WA317978718 - ALLIANCE MACHINE SYSTEMS INTERNATIONAL LLC
SPOKANE, WA—2023-01-24 00:00:00
WA317972263 - ALLIANCE MACHINE SYSTEMS INTERNATIONAL LLC
COLUMBUS, MS—2020-02-18 00:00:00
VALMET, INC.
More inspections in NH
CONCORD, NH—2026-07-10
C.C. TOMATOES
FRANCESTOWN, NH—2026-07-10
JM BUILDERS LLC
FRANCESTOWN, NH—2026-07-10
D&D INSULATION, LLC
NORTHFIELD, NH—2026-07-03
JP PEST SERVICES
CONCORD, NH—2026-07-01
REYES CARPENTRY, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338965627.