Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CARR LANE CASTINGS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CARR LANE CASTINGS, INC. in 4100 CARR LANE COURT, SAINT LOUIS, MO 63119 (NAICS 331316). OSHA activity number 338969835.

Watch Carr Lane Castings, INC. — free Get an email when a new federal OSHA severe-injury report for Carr Lane Castings, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4100 CARR LANE COURT
City
SAINT LOUIS
State
MO
ZIP
63119
Mailing
4100 CARR LANE COURT, SAINT LOUIS, MO 63119
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331316
Employees
12
Ownership type
A

3 citations on file for this inspection.

1910.178 P01

Serious Gravity 1 1 instance 9 exposed
Issued
Penalty
Initial $1020.00 · Current $714.00 Reduced
29 CFR 1910.178(p)(1):     If at any time a powered industrial truck is found to be in need of repair, defective, or in any way unsafe, the truck shall be taken out of service until it has been restored to safe operating condition.    1. At the time of the inspection, inside of the production area, employees were operating a Hyster model 50 propane powered fork truck with an inoperable horn.
Recent events (2)
  • — I (S) $714
  • — Z (S) $1020

1910.304 G05

Serious Gravity 1 3 instances 9 exposed
Issued
Penalty
Initial $1020.00 · Current $714.00 Reduced
29 CFR 1910.304(g)(5):     Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent, continuous, and effective.    1. Inside of the inspection and finishing area, employees were using a small metal scale that was located on a table that was not grounded. The metal casing (framing) on the scale was energized (hot). The small scale was GSE Model 574 scale system and serial number 109199.    2. Inside of the inspection and finishing area, employees were using a large blue metal scale that located on the floor that was not grounded. The metal casing (framing) on the scale was energized (hot). The large scale was a Weight-Tronix Model DSL 4848-05 with a weight capacity of 5,000 pounds.     3. On the second floor, employees were using a yellow Kenmore refrigerator that was not grounded. The metal casing (framing) on the appliance was energized (hot). The ground pin was missing from the plug of the electrical cord used to energize the refrigerator.
Recent events (2)
  • — I (S) $714
  • — Z (S) $1020

1910.179 B02

Other-than-serious 2 instances 12 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.179(b)(2):     New and existing equipment. All new overhead and gantry cranes constructed and installed on or after August 31, 1971, shall meet the design specifications of the American National Standard Safety Code for Overhead and Gantry Cranes, ANSI B30.2.0-1967, which is incorporated by reference as specified in Sec. 1910.6.    1. At the time of the inspection, in the air set department, employees were operating a 2 ton over head crane with no safety tag in place above the pendant control box    2. At the time of the inspection, on the second floor balcony, employees were operating a 2 ton over head crane with no safety tag in place above the pendant control box.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338969835.