DAYTONA BEACH, FL —
OSHA Inspection: POWER FLOW SYSTEMS, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of POWER FLOW SYSTEMS, INC. in 1585 AVIATION CENTER PKWY SUITE 804, DAYTONA BEACH, FL 32114 (NAICS 336412). OSHA activity number 338974108.
Where did this inspection happen?
- Establishment
- POWER FLOW SYSTEMS, INC.
- Site address
- 1585 AVIATION CENTER PKWY SUITE 804
- City
- DAYTONA BEACH
- State
- FL
- ZIP
- 32114
- Mailing
- 1585 AVIATION CENTER PKWY SUITE 804, DAYTONA BEACH, FL 32114
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336412
- Employees
- 12
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.1026 D01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
0689
General-duty citation text
29 CFR 1910.1026(d)(1): The employer with a workplace or work operation covered by this standard did not determine the 8-hour time-weighted average exposure for each employee exposed to chromium (VI): a. On or about March 26, 2013, the employer did not perform initial exposure monitoring for chromium (VI) on employees who welded materials made of stainless steel. ABATEMENT CERTIFICATION AND DOCUMENTATION ARE NOT REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a. On or about March 26, 2013, the employer did not develop and implement the written hazard communication program which described how requirements of 29 CFR 1910.1200(f), (g), and (h) would be met for employees who have exposure to hazardous materials such as but not limited to acetone, propylene glycol ethers, and chromium (VI).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 H01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a. On or about March 26, 2013, the employer did not provide information and training to employees who have exposure to hazardous materials such as but not limited to acetone, propylene glycol ethers, and chromium (VI).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at POWER FLOW SYSTEMS, INC.
DAYTONA BEACH, FL—2017-06-28 00:00:00
POWER FLOW SYSTEMS, INC.
DAYTONA BEACH, FL—2014-12-16 00:00:00
POWER FLOW SYSTEMS, INC.
View POWER FLOW SYSTEMS, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 336412)
STUART, FL—2026-06-16
TURBOCOMBUSTOR TECHNOLOGY, INC.
TRAVERSE CITY, MI—2026-06-15
SKILLED MANUFACTURING INC
WHITEHALL, MI—2026-06-02
HOWMET AEROSPACE INC
HILLSDALE, MI—2026-05-12
COBRA MOTO LLC
MADISONVILLE, KY—2026-04-21
69032 - GENERAL ELECTRIC COMPANY
More inspections in FL
MARIANNA, FL—2026-07-13
PRIMETIME MOBILE MASONRY LLC