Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DUCKTRAP RIVER OF MAINE, LLC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DUCKTRAP RIVER OF MAINE, LLC. in 57 LITTLE RIVER DRIVE, BELFAST, ME 04915 (NAICS 311711). OSHA activity number 338980030.

Watch Ducktrap River OF Maine, LLC. — free Get an email when a new federal OSHA severe-injury report for Ducktrap River OF Maine, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
57 LITTLE RIVER DRIVE
City
BELFAST
State
ME
ZIP
04915
Mailing
57 LITTLE RIVER DRIVE, BELFAST, ME 04915
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311711
Employees
120
Ownership type
A

4 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3375.00 · Current $2531.00 Reduced
29 CFR 1910.23(c)(1):   Every open-sided floor or platform 4 feet or more above adjacent floor or ground level shall be guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides.    Parts Storage Area - The overhead light bulb storage and roof access platform 10 feet above the floor was not provided with standard railings.
Recent events (2)
  • — I (S) $2531.25
  • — Z (S) $3375

1910.242 B

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $2025.00 · Current $1519.00 Reduced
29 CFR 1910.242(b):   Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment.    Maintenance Shop - Compressed air used for cleaning was not reduced to less than 30 p.s.i.
Recent events (2)
  • — I (S) $1518.75
  • — Z (S) $2025

1910.178 P01

Other-than-serious 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(p)(1):     If at any time a powered industrial truck is found to be in need of repair, defective, or in any way unsafe, the truck shall be taken out of service until it has been restored to safe operating condition.    Toyota Electric Truck 7HBW2325474 - The load backrest was missing two lower bolts.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.219 C02 I

Other-than-serious 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.219(c)(2)(i):    All exposed parts of horizontal shafting seven (7) feet or less from floor or working platform shall be protected by a stationary casing enclosing shafting completely or by a trough enclosing sides and top or sides and bottom of shafting as location requires.    Shipping - The line shaft on the shipping conveyor was not guarded or fully enclosed.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338980030.