BELOIT, WI —
OSHA Inspection: SANDERS CONSTRUCTION INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SANDERS CONSTRUCTION INC. in 2919 SOUTH PARK AVENUE, BELOIT, WI 53511 (NAICS 238130). OSHA activity number 338981541.
Where did this inspection happen?
- Establishment
- SANDERS CONSTRUCTION INC.
- Site address
- 2919 SOUTH PARK AVENUE
- City
- BELOIT
- State
- WI
- ZIP
- 53511
- Mailing
- 9504 NORTH ALPINE ROAD, MACHESNEY PARK, IL 61115
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 5
- Ownership type
- A
Citations
4 citations on file for this inspection.
1903.19 C01
- Issued
- Abate by
- Penalty
- Initial $400.00 · Current $400.00
General-duty citation text
29 CFR 1903.19(c)(1): Within 10 calendar days after the abatement date, the employer must certify to OSHA (the Agency) that each cited violation has been abated, except as provided in paragraph (c)(2) of this section. The employer did not certify that the following cited items have been abated: 1. Employees installing roof sheathing at a height of six feet were not using fall protection. 2. Employees performing roofing activities were not trained on how to recognize fall hazards or how to protect themselves against fall hazards. 3. Employees were using a portable ladder that did not extend three feet beyond the landing surfac nor was it secured to prevent displacement.
Recent events (1)
- — Z (O) $400
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $2400.00 · Current $2400.00
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: On or about March 28, 2013, employees working from roof deck / trusses installing sheathing at a height greater than six feet were doing so without fall protection.
Recent events (1)
- — Z (S) $2400
1926.503 A02 VIII
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1926.503(a)(2)(viii): The employer did not assure that each employee had been trained by a competent person qualified in the standards contained in subpart M: The individuals on site were not familiar with the OSHA fall protection standards and the requirements held within.
Recent events (1)
- — Z (S) $1600
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. On or about March 28, 2013, employees were utilizing a portable ladder that did not extend three feet passed the landing surface nor was it secured to prevent displacement.
Recent events (1)
- — Z (S) $1600
More inspections at SANDERS CONSTRUCTION INC.
VIRGINIA BEACH, VA—2016-03-02 00:00:00
SANDERS CONSTRUCTION INC
VALLEY CENTER, CA—2007-01-31 00:00:00
SANDERS CONSTRUCTION INC.
OVERLAND PARK, KS—2006-04-27 00:00:00
SANDERS CONSTRUCTION INC
CAMAS, WA—2005-09-07 00:00:00
SANDERS CONSTRUCTION INC
CHAPIN, SC—2004-04-08 00:00:00
SANDERS CONSTRUCTION, INC.
View SANDERS CONSTRUCTION INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238130)
FAIRHOPE, AL—2026-07-16
FRANCISCO ARES
WOODHAVEN, MI—2026-07-16
G.J. PERELLI CO., L.L.C.
PHILADELPHIA, PA—2026-07-16
URUS CONSTRUCTION CORPORATION
BERLIN, NJ—2026-07-16
URUS CONSTRUCTION CORPORATION
MERIDIAN, ID—2026-07-15
TRIPLE R CONSTRUCTION LLC
More inspections in WI
WAUSAU, WI—2026-07-16
MIRON CONSTRUCTION CO. INC.
ELROY, WI—2026-07-15
WABASH NATIONAL SERVICES, L.P.
SUSSEX, WI—2026-07-15
KINGS SUPERIOR CONSTRUCTION LLC
DELAVAN, WI—2026-07-15
TERONOMY BUILDERS, INC.
DELAVAN, WI—2026-07-15
A. GOMEZ CARPENTRY, INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338981541.