Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SYMPHONY PASTERIES INC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of SYMPHONY PASTERIES INC in 1263 GLEN AVE SUITE 220, MOORESTOWN, NJ 08057 (NAICS 311340). OSHA activity number 338986250.

Watch Symphony Pasteries INC — free Get an email when a new federal OSHA severe-injury report for Symphony Pasteries INC is published. One employer, no account, unsubscribe in one click.
Site address
1263 GLEN AVE SUITE 220
City
MOORESTOWN
State
NJ
ZIP
08057
Mailing
1263 GLEN AVE SUITE 220, MOORESTOWN, NJ 08057
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311340
Employees
19
Ownership type
A

12 citations on file for this inspection.

1910.133 A01

Serious Gravity 5 1 instance 18 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1400.00 Reduced
29 CFR 1910.133(a)(1): Protective eye equipment was not required where there was a reasonable probability of injury that could be prevented by such equipment:     a) Dishwashing area: The employer did not provide and ensure that employees used goggles when working with corrosive chemicals, such as, but not limited to, bleach, Jewel Oven, Grill and Fryer Cleaner, on or about 4/2/13.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

1910.151 C

Serious Gravity 5 1 instance 18 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:   a) Dishwashing area: An eyewash station, capable of 15 minutes of continuous flushing, was not provided where employees used corrosive chemicals, such as, but not limited to, bleach and Jewel Oven, Grill and Fryer Cleaner, on or about 4/2/13.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1120.00 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure(s), employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    a) Prep area: The employer did not develop and implement a lockout tagout program, including energy control procedures, training and periodic inspections, for equipment that was cleaned by employees, such as, but not limited to three Hobart mixers and a Metronics Technologies water cutting machine model 172LC serial 70172LC,  on or about 4/2/13.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

1910.178 L04 III

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1120.00 Reduced
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years:    a) Shipping/receiving area: An evaluation of each powered industrial truck operator who operated the Raymond and Northeast Blue Giant electric pallet jacks was not conducted every three years, on or about 4/2/13.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

1910.303 G01 II

Serious Gravity 1 2 instances 19 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $840.00 Reduced
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:     a) Prep area: Electrical panels that powered such things as, but not limited to, stationary mixers, were blocked by stored mixing bowls,  on or about 4/2/13.     b) Shipping/receiving area: Electrical panels that powered such things as, but not limited to, the ovens, compressor and microwave were blocked by two floor cleaners, on or about 4/2/13.
Recent events (2)
  • — I (S) $840
  • — Z (S) $1200

1910.305 G01 IV A

Serious Gravity 1 4 instances 19 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $840.00 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:    a) Prep area: An extension cord reel was used to power a depositor machine,  on or about 4/2/13.     b) Prep area mixer area: A power strip was used to power two scales located in the mixing area, on or about 4/2/13.    c) Packaging area: A power strip was used to power a Little David Microject Printer and Loveshaw Corporation Conveyor to stamp the date on the inside of product boxes, on or about 4/2/13.    d) Packaging area: A power strip was used to power a Little David Microjet Printer and 3M Tape Sealer, on or about 4/2/13.
Recent events (2)
  • — I (S) $840
  • — Z (S) $1200

1910.305 G01 IV B

Serious Gravity 1 1 instance 19 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $840.00 Reduced
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and/or cables were run through holes in walls, ceilings, or floors:        a) Throughout facility: The permanent connection of drop down electrical cords to junction boxes were run through holes in drop ceiling panels,  on or about 4/2/13.
Recent events (2)
  • — I (S) $840
  • — Z (S) $1200

1910.305 G01 IV D

Serious Gravity 1 1 instance 19 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords were attached to building surfaces:     a) Packaging area: Three drop down electrical cords were attached to the metal frame of the drop down ceiling,  on or about 4/2/13.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 1 1 instance 19 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $840.00 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:    a) Prep area next to mixers: A cord powering outlets on a prep table that powered a microwave, mixer and a power strip had a torn strain relief, on or about 4/2/13.
Recent events (2)
  • — I (S) $840
  • — Z (S) $1200

1910.1200 E01

Serious Gravity 5 1 instance 19 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1400.00 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:     a) Throughout facility: The employer did not develop and implement a written hazard communication program for the hazardous chemicals used by employees, such as, but not limited to bleach (a corrosive), Jewel Oven Fryer and Grill Cleaner (a corrosive), Jewel Fastmatic, Deluxe Dishwashing Detergent (a corrosive) and WD40, on or about 4/2/13.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

1910.1200 G01

Serious Gravity 5 1 instance 19 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use:   a) Throughout facility: The employer did not  maintain safety data sheets for the hazardous chemicals used by employees, such as, but not limited to bleach (a corrosive), Jewel Oven Fryer and Grill Cleaner (a corrosive), Jewel Fastmatic, Deluxe Dishwashing Detergent (a corrosive) and WD40, on or about 4/2/13.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H01

Serious Gravity 5 1 instance 19 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:    a) Throughout facility: The employer did not  provide information and training to employees for the hazardous chemicals used in the facility, such as, but not limited to bleach (a corrosive), Jewel Oven Fryer and Grill Cleaner (a corrosive), Jewel Fastmatic, Deluxe Dishwashing Detergent (a corrosive) and WD40, on or about 4/2/13.