HOUSTON, TX —
OSHA Inspection: HOUSTON TRANSFORMER COMPANY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HOUSTON TRANSFORMER COMPANY in 5725 BRAXTON DRIVE, HOUSTON, TX 77036 (NAICS 335311). OSHA activity number 338988603.
Where did this inspection happen?
- Establishment
- HOUSTON TRANSFORMER COMPANY
- Site address
- 5725 BRAXTON DRIVE
- City
- HOUSTON
- State
- TX
- ZIP
- 77036
- Mailing
- 5725 BRAXTON DRIVE, HOUSTON, TX 77036
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 335311
- Employees
- 85
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.141 A03
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $2100.00 Reduced
General-duty citation text
29 CFR 1910.141(a)(3): The employer did not ensure that all places of employment were kept clean to the extent that the nature of the work allowed. (a) In the machine shop, on or about April 3, 2013 - Oil leaking from the pressure release component of the Harrison centre lathe, model number M400, created a slipping/fall hazard.
Recent events (2)
- — I (S) $2100
- — Z (S) $3500
1910.212 A03 II
- Issued
- Abate by
- Penalty
- Initial $4200.00 · Current $2520.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a) In the Assmebly area, on or before April 3, 2013 - The Guangri Toroidal Winding Machine (MN 6204 SN 20006204A205) lacked a guard at the point of operation. b) In the machine shop, on or about April 3, 2013 - The PACIFIC qaurter ton Press Brake (MN J55-6 SN 8832) lacked guarding at the point of operation.
Recent events (2)
- — I (S) $2520
- — Z (S) $4200
More inspections at HOUSTON TRANSFORMER COMPANY
HOUSTON, TX—2013-05-21 00:00:00
HOUSTON TRANSFORMER COMPANY
View HOUSTON TRANSFORMER COMPANY's full OSHA safety record →
More inspections in this industry (NAICS 335311)
SANTA ANA, CA—2026-06-04
EATON CORPORATION
TROUTVILLE, VA—2026-05-15
VIRGINIA TRANSFORMER CORP.
WASHINGTON, MO—2026-05-11
WEG TRANSFORMERS USA LLC
WASHINGTON, MO—2026-05-05
WEG TRANSFORMERS USA LLC
TROUTVILLE, VA—2026-04-29
VIRGINIA TRANSFORMER CORP.
More inspections in TX
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
FORT WORTH, TX—2026-07-10
RC PROFESSIONAL ROOFING OF TEXAS LLC
CYPRESS, TX—2026-07-10
FEDERICO CARVAJAL GARCIA
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
SAN ANTONIO, TX—2026-07-09
WAREHOUSE RACK COMPANY, LP
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338988603.