Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DIXIE ELECTRO PLATING COMPANY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DIXIE ELECTRO PLATING COMPANY in 3001 ENGELKE STREET, HOUSTON, TX 77003 (NAICS 332813). OSHA activity number 338994635.

Watch Dixie Electro Plating Company — free Get an email when a new federal OSHA severe-injury report for Dixie Electro Plating Company is published. One employer, no account, unsubscribe in one click.
Site address
3001 ENGELKE STREET
City
HOUSTON
State
TX
ZIP
77003
Mailing
3001 ENGELKE STREET, HOUSTON, TX 77003
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332813
Employees
33
Ownership type
A

4 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1800.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:     In the polishing room, on June 13, 2013 and at times prior thereto; employees were operating two lathes that were modified with a belt sander attachment to polish drilling well pipes. Employees polishing the drilling tubes were exposed to rotating parts, and caught in between hazards.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $2800

1910.303 E01 II

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $1200.00 Reduced
29 CFR 1910.303(e)(1)(ii): Electric equipment shall not be used unless markings have been placed on equipment such as voltage, current, wattage and other ratings as necessary:    At the job site, on June 13, 2013 and at times prior thereto; employees working in their designated areas and maintenance personnel were exposed to electrical equipment that was not properly marked, exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2100

1910.215 A04

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:     In the tooling area, on June 13, 2013 and at times prior thereto; employees used a Dayton 10 inch bench grinder with the work rest not adjusted properly, exposing employees to struck-by hazards and amputations.
Recent events (2)
  • — I (S) $2800
  • — Z (S) $2800

1910.215 B09

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $0.00 Reduced
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:     In the tooling area, on June 13, 2013 and at times prior thereto; employees used a Dayton 10 inch bench grinder with the tongue guard missing and could not be adjusted properly, exposing employees to struck-by hazards and amputations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2100

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338994635.