2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: PRAVCO INDUSTRIAL

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PRAVCO INDUSTRIAL in 111 E. HILLCREST RD., FRANCIS CREEK, WI 54214 (NAICS 423830). OSHA activity number 338995012.

Watch Pravco Industrial — free Get an email when a new federal OSHA severe-injury report for Pravco Industrial is published. One employer, no account, unsubscribe in one click.
Establishment
PRAVCO INDUSTRIAL
Site address
111 E. HILLCREST RD.
City
FRANCIS CREEK
State
WI
ZIP
54214
Mailing
PO BOX 217, FRANCIS CREEK, WI 54214
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423830
Employees
10
Ownership type
A

7 citations on file for this inspection.

1910.178 P01

Serious Gravity 10 2 instances 10 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $600.00 Reduced
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s):     a) On or about April 8 2013 and, at times prior to, the Datsun LP forklift did not have functioning brakes and the lift truck was not taken out of service until a time such repairs had been made.     Abatement Certification and Abatement Documentation Required.
Recent events (3)
  • — F (S) $600
  • — C (S) $2800
  • — Z (S) $2800

1910.178 P04

Serious Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(p)(4): No truck shall be operated with a leak in the fuel system until the leak has been corrected:  a) The Linde diesel forklift was leaking fuel while it was being utilized at a customer's site.   Abatement Certification and Abatement Documentation Required.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.215 A02

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $1360.00 · Current $600.00 Reduced
29 CFR 1910.215(a)(2): Abrasive wheel(s) used on grinding machinery were not provided with safety guard(s) which covered the spindle end, nut, flange projections:    a) On or about April 8, 2013, the pedestal grinder used in the maintenance area did not have a side guard installed on the grinder to prevent employee exposure to the rotating spindle end, nut and flange projections.     No Abatement Certification or Abatement Documentation Required.
Recent events (3)
  • — F (S) $600
  • — C (S) $1360
  • — Z (S) $1360

1910.215 A04

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:  a) On or about April 8, 2013, the pedestal grinder used in the maintenance area did not have the work rest adjusted to the maximum allowable opening of one eighth inch or less while employees were operating the grinder.   No Abatement Certification or Abatement Documentation Required.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.215 B09

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  a) On or about April 8, 2013, the pedestal grinder used in the maintenance area did not have a tongue guard installed and adjusted to prevent employee exposure to the nip point hazard.   No Abatement Certification or Abatement Documentation Required.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.253 B04 III

Serious Gravity 5 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $800.00 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least an hour:     a) On or about April 8, 2013, one acetylene cylinder and one liquified petroleum cylinder were stored next to three oxygen cylinders without a noncombustible barrier at least 5 feet high or were separated by a minimum distance of twenty (20) feet in the maintenance/storage shop.     No Abatement Certification or Abatement Documentation Required.
Recent events (3)
  • — F (S) $800
  • — C (S) $2000
  • — Z (S) $2000

1910.253 B02 IV

Other-than-serious 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use:  a) On or about April 8, 2013, one acetylene cylinder was stored without the protection valve cap in place over the valve stem.    Abatement Certification Required.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338995012.