Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CENTRAL SUBSURFACE CONTRACTING OF ILLINOIS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CENTRAL SUBSURFACE CONTRACTING OF ILLINOIS, INC. in VIRGINIA STREET AND WING AVENUE, WAGGONER, IL 62572 (NAICS 237110). OSHA activity number 338997406.

Watch Central Subsurface Contracting OF Illinois, INC. — free Get an email when a new federal OSHA severe-injury report for Central Subsurface Contracting OF Illinois, INC. is published. One employer, no account, unsubscribe in one click.
Site address
VIRGINIA STREET AND WING AVENUE
City
WAGGONER
State
IL
ZIP
62572
Mailing
13960 SPILLWAY ROAD, GIRARD, IL 62640
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
9
Ownership type
A

6 citations on file for this inspection.

1926.20 B01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2400.00 · Current $0.00 Reduced
29 CFR 1926.20(b)(1):  The employer did not initiate and maintain accident prevention programs as necessary to comply with this part:    Employees performing underground water line installation were exposed to trenching hazards and the employer did not maintain an accident prevention program as necessary to comply with the standard.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2400

1926.651 K01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions:     Employees performing underground water line installation were exposed to trenching hazards and the employer did not ensure daily inspections of excavations and adjacent areas were made by a competent person for evidence of a situation that could have resulted in possible hazardous conditions.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.20 B02

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1926.20(b)(2):  The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s):    Employees performing underground water line installation were exposed to vehicular traffic struck-by hazards and the employer did not ensure safety programs provided for frequent and regular inspection by a competent person.
Recent events (2)
  • — I (O) $1600
  • — Z (S) $1600

1926.200 G01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.200(g)(1): Construction areas were not posted with legible traffic signs at points of hazards:     Employees performing underground water line installation were exposed to vehicular traffic struck-by hazards and the employer did not ensure construction areas were posted with legible traffic signs at points of hazards.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.651 C02

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2400.00 · Current $2400.00
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:    Employees performing underground water line installation at a depth of 53 inches were exposed to trenching hazards and the employer did not ensure a safe means of egress was available for trenches 4 feet or more in depth.
Recent events (2)
  • — I (O) $2400
  • — Z (S) $2400

1926.651 J02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2400.00 · Current $1680.00 Reduced
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary:     Employees performing underground water line installation were exposed to trenching hazards and the employer did not ensure excavated materials were placed at least 2 feet from the edge of excavations.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2400

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338997406.