Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JC POWER TECH INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JC POWER TECH INC. in VILLA MARINA, FAJARDO, PR 00738 (NAICS 443112). OSHA activity number 339000374.

Watch JC Power Tech INC. — free Get an email when a new federal OSHA severe-injury report for JC Power Tech INC. is published. One employer, no account, unsubscribe in one click.
Establishment
JC POWER TECH INC.
Site address
VILLA MARINA
City
FAJARDO
State
PR
ZIP
00738
Mailing
PO BOX 7336, CAGUAS, PR 00726
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
443112
Employees
11
Ownership type
A

1 citation on file for this inspection.

1910.67 C02 V

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1440.00 · Current $936.00 Reduced
29 CFR 1910.67(c)(2)(v): A body belt was not worn and a lanyard attached to the boom or basket when working from an aerial lift:      a.    On or about 10 Apr 2013, west side VIP Marina section, Villa Marina, Fajardo, PR.  Employees engaged in a banner's installation have been working from a manlift at approximately 20 feet from the ground level without the use of personal fall arrest systems.         NOTE:  Certification of abatement is not required for this citation item as abatement was documented by the compliance safety and health officer during the inspection.
Recent events (2)
  • — I (S) $936
  • — Z (S) $1440