BLOOMFIELD, NJ —
OSHA Inspection: PRISM CONSTRUCTION MANAGEMENT, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PRISM CONSTRUCTION MANAGEMENT, LLC in 5 LAWRENCE STREET, BLOOMFIELD, NJ 07003 (NAICS 236116). OSHA activity number 339001000.
Where did this inspection happen?
- Establishment
- PRISM CONSTRUCTION MANAGEMENT, LLC
- Site address
- 5 LAWRENCE STREET
- City
- BLOOMFIELD
- State
- NJ
- ZIP
- 07003
- Mailing
- 200 BROADACRES DR, BLOOMFIELD, NJ 07003
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236116
- Employees
- 40
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.403 B02
- Issued
- Penalty
- Initial $4200.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a. 5 Lawrence Street, Bloomfield, NJ - Parkway Lofts Project - Throughout the building. Electrical outlet drop boxes were not installed and used in a accordance with the instructions included in the listing and certification. Sub-contractor employees used drop boxes that were not mounted in accordance with the instructions included in the listing or labeling, as a source of electrical power for hand tools. Violation observed on or about April 11, 2013
Recent events (2)
- — I (S) $0
- — Z (S) $4200
1926.405 A02 II E
- Issued
- Penalty
- Initial $2800.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(E): Lamps used in temporary wiring for general illumination were not protected from accidental contact or breakage. a) 5 Lawrence Street, Bloomfield, NJ - 5th floor staircase Lamps used in the stairways for temporary lighting were not protected from accidental damage by a cover by employees or sub-contractor employees. Violation observed on or about April 11, 2013
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1926.501 B01
- Issued
- Abate by
- Penalty
- Initial $4900.00 · Current $3119.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a. 5 Lawrence Street, Bloomfield, NJ - Parkway Lofts Project - West side, south end, 2nd and 3rd floor. Sub-contractor employees on walking/working surfaces at the south end, west side 2nd and 3rd floors were not protected from falling to the next lower level by use of a guardrail system, a safety net system, or personal fall arrest systems. Sub-contractor employees were exposed to 11 to 22 foot fall hazards. Violation observed on or about April 11, 2013 b. 5 Lawrence Street, Bloomfield, NJ - Parkway Lofts Project - 2nd level ,south end, near exterior of elevator shafts 3 & 4. Sub-contractor employees performing concrete drilling activities an walking/working surface adjacent to elevator shafts 3 & 4 were not protected from falling to the next lower level by use of a guardrail system, a safety net system, or personal fall arrest systems. Sub-contractor employees were exposed to 11-foot fall hazards. Violation observed on or about April 11, 2013 c. 5 Lawrence Street, Bloomfield, NJ - Parkway Lofts Project - Center building near lobby stairs. Sub-contractor employees on walking/working surface adjacent to the center lobby staircase were not protected from falling to the next lower level by use of a guardrail system, a safety net system, or personal fall arrest systems. Sub-contractor employees were exposed to 11-foot fall hazards. Violation observed on or about April 11, 2013
Recent events (2)
- — I (S) $3118.5
- — Z (S) $4900
1926.502 I03
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $3119.00 Reduced
General-duty citation text
29 CFR 1926.502(i)(3): All covers were not secured when installed so as to prevent accidental displacement by the wind, equipment, or employees. a. 5 Lawrence Street, Bloomfield, NJ - Parkway Lofts Project - 7th Floor, North end The employer did not provide a secure cover for a 2 foot by 5-foot floor hole. Violation observed on or about April 11, 2013
Recent events (2)
- — I (S) $3118.5
- — Z (S) $3500
1926.502 I04
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $3119.00 Reduced
General-duty citation text
29 CFR 1926.502(i)(4): All covers were not color coded or marked with the word HOLE or COVER to provide warning of the hazard. a. 5 Lawrence Street, Bloomfield, NJ - Parkway Lofts Project - North end, 7th floor. Employer did not ensure floor hole cover was marked to provide a warning of the hazard. Pallet material was used as a floor hole cover and was not colored or marked to provide warning of the 17-foot fall hazard. Violation observed on or about April 11, 2013
Recent events (2)
- — I (S) $3118.5
- — Z (S) $3500
1926.1052 C01
- Issued
- Abate by
- Penalty
- Initial $4200.00 · Current $3119.00 Reduced
General-duty citation text
29 CFR 1926.1052(c)(1): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail and one stair rail system along each unprotected side or edge. a. 5 Lawrence Street, Bloomfield, NJ - Parkway Lofts Project - Center Lobby Staircase Stairway at the center lobby area had 11 risers to the mid landing, and 8 risers to the top landing were not equipped with at least one handrail on the unprotected edge. Violation observed on or about April 11, 2013
Recent events (2)
- — I (S) $3118.5
- — Z (S) $4200
1926.1052 C12
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1052(c)(12): Unprotected sides and edges of stairway landings were not provided with guardrail systems that meet the criteria contained in Subpart M of 29 CFR 1926. a. 5 Lawrence Street, Bloomfield, NJ - Parkway Lofts Project - Center building, lobby staircase The employer did not provide a guardrail system on the unprotected sides of the stairway landings. Violation was observed on or about April 11, 2013
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 236116)
PLAIN CITY, OH—2026-07-09
RUSCILLI CONSTRUCTION
IRVINE, CA—2026-07-09
TOLL BROTHERS INC.
ROSEVILLE, CA—2026-07-09
JERRY LEE STAIRS INC.
NEWPORT, RI—2026-07-08
PEZZUCO CONSTRUCTION INC.
EVANSVILLE, IN—2026-07-08
L & J CONSTRUCTORS, LLC
More inspections in NJ
FREEHOLD, NJ—2026-07-10
MARIO & SONS CONSTRUCTION GROUP, LLC
FREEHOLD, NJ—2026-07-10
VACCA ROOFING
FREEHOLD, NJ—2026-07-10
SPECTRA PAINTING, INC
FREEHOLD, NJ—2026-07-10
CRAIG'S MASONRY & HARDSCAPE LLC
FREEHOLD, NJ—2026-07-10
GTN CONSTRUCTION INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339001000.