CHERRYFIELD, ME —
OSHA Inspection: TIM'S ROOFING & RENOVATIONS LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of TIM'S ROOFING & RENOVATIONS LLC in WILSON HILL ROAD, CHERRYFIELD, ME 04622 (NAICS 238160). OSHA activity number 339012593.
Where did this inspection happen?
- Establishment
- TIM'S ROOFING & RENOVATIONS LLC
- Site address
- WILSON HILL ROAD
- City
- CHERRYFIELD
- State
- ME
- ZIP
- 04622
- Mailing
- 32 WILLEY DISTRICT ROAD, CHERRYFIELD, ME 04622
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.1053 B09
- Issued
- Abate by
- Penalty
- Initial $2200.00 · Current $1430.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(9): The area around the top and bottom of ladders shall be kept clear. Narraguagus Lodge - A scaffold plank was protruding through the top of the extension ladder.
Recent events (2)
- — I (S) $1430
- — Z (S) $2200
1926.451 G01
- Issued
- Abate by
- Penalty
- Initial $6160.00 · Current $4004.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers. Note to paragraph (g)(1): The fall protection requirements for employees installing suspension scaffold support systems on floors, roofs, and other elevated surfaces are set forth in subpart M of this part. Narraguagus Lodge - The employees on the fabricated frame scaffold 24 feet above the ground were not protected from falling. Tim's Roofing and Renovations LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 314426826, Citation 1, Item 1 and was affirmed as a final order on 6/3/2010, with respect to a workplace located at Cherryfield, Maine.
Recent events (2)
- — I (R) $4004
- — Z (R) $6160
1926.451 B01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform). Narraguagus Lodge - The space between the scaffold planks exceeded 1 inch.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. Narraguagus Lodge - The side rails of the extension ladder did not extend 3 feet above the scaffold platform.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in ME
PORTLAND, ME—2026-07-06
NEW ENGLAND REHABILITATION HOSPITAL OF PORTLAND