Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: JUAN CARLOS CLIMACO

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JUAN CARLOS CLIMACO in 841 FOWLER ST., ATLANTA, GA 30313 (NAICS 238170). OSHA activity number 339028151.

Watch Juan Carlos Climaco — free Get an email when a new federal OSHA severe-injury report for Juan Carlos Climaco is published. One employer, no account, unsubscribe in one click.
Establishment
JUAN CARLOS CLIMACO
Site address
841 FOWLER ST.
City
ATLANTA
State
GA
ZIP
30313
Mailing
2172 OAKLAND DR., LAWRENCEVILLE, GA 30044
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
3
Ownership type
A

5 citations on file for this inspection.

1926.452 J02

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary.    a) 841 Fowler Street, Atlanta GA  The employer exposed employees to a lower level fall hazard of approximately 30 - feet while working from a pump jack scaffold that was not braced at the bottom and intermediate areas.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.451 G03

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1926.451(g)(3): Personal fall arrest systems used on scaffolds were not attached by lanyard to a vertical lifeline, horizontal lifeline, or scaffold structural member.    a) 841 Fowler Street, Atlanta GA  The employer exposed an employee to a lower level fall hazard of approximately 30 - feet while working from a pump jack scaffold. The employee was not connected to the vertical lifeline.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1926.502 D16 III

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level:  a) 841 Fowler Street, Atlanta GA  The employer exposed an employee to a free fall hazard of over 6-feet by not adjusting the deceleration device attached to a vertical lifeline to limit the fall distance.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 G03 I

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(g)(3)(i): Vertical lifelines were not protected from sharp edges and abrasion.  a) 841 Fowler Street, Atlanta GA - The employer did not ensure vertical lifelines used with personal fall arrest systems were protected from abrasions and sharp edges.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.502 D06 I

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.502(d)(6): Locking snaphooks used on lanyards were not designed to engage directly to webbing, rope or wire rope.   a) 841 Fowler Street, Atlanta GA  The employer allowed snaphooks on vertical lifelines used for personal fall arrest to be engaged direct onto the rope.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339028151.