Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DEMELLO AND SORLI ENTERPRISES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DEMELLO AND SORLI ENTERPRISES, INC. in 46 HOOLAI ST, KAILUA, HI 96734 (NAICS 311812). OSHA activity number 339041766.

Watch Demello AND Sorli Enterprises, INC. — free Get an email when a new federal OSHA severe-injury report for Demello AND Sorli Enterprises, INC. is published. One employer, no account, unsubscribe in one click.
Site address
46 HOOLAI ST
City
KAILUA
State
HI
ZIP
96734
Mailing
46 HOOLAI ST, KAILUA, HI 96734
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311812
Employees
15
Ownership type
A

2 citations on file for this inspection.

1910.147 C01

Serious Gravity 5 2 instances 7 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:   The employer failed to protect employees from potential electrical, caught between and amputation hazards associated with performing maintenance on equipment requiring the de-energizing of stored energy without having developed and implemented a written lockout and tag out program.  This was most recently evident during the inspection of the facility located at 46 Hoolai Street, Kailua, HI 96734, where the employer has employees and outside contractors working on baking ovens without having a written lockout and tag out program in place to establish the necessary safety methods to prevent injury.  Instances include but are not limited to:    i.  A month ago the owner of the company performed maintenance on the oven without applying any locks to the circuit breaker to prevent the accidental restart of the oven with thermal and electric stored energy.     ii. A month and a half ago the employer had an outside contractor working on the big oven without having established whose written procedures shall be used to ensure that all stored energy is isolated.
Recent events (1)
  • — Z (S) $2000

1910.212 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  The employer failed to protect employees from potential amputation hazards associated with operating unguarded bakery mixers.  This was most recently evident during the inspection of the facility located at 46 Hoolai Street, Kailua, HI 96734, where the employer has employees operating the unguarded Hobart mixer model # 11-38-847, serial # 0-300 in the process to make cookie and cakes.
Recent events (1)
  • — Z (S) $2800

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339041766.