STRATFORD, CT —
OSHA Inspection: MCMELLON BROS., INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MCMELLON BROS., INC. in 915 HONEYSPOT ROAD, STRATFORD, CT 06615 (NAICS 336413). OSHA activity number 339062978.
Where did this inspection happen?
- Establishment
- MCMELLON BROS., INC.
- Site address
- 915 HONEYSPOT ROAD
- City
- STRATFORD
- State
- CT
- ZIP
- 06615
- Mailing
- 915 HONEYSPOT ROAD, STRATFORD, CT 06615
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336413
- Employees
- 29
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.157 D01
- Issued
- Abate by
- Penalty
- Initial $2100.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.157(d)(1): Portable fire extinguishers shall be provided for employee use and selected and distributed based on the classes of anticipated workplace fires and on the size and degree of hazard which would affect their use. WORKPLACE: The employer did not select and provide fire extinguishers based on the types of fires anticipated in the workplace.
Recent events (2)
- — I (S) $0
- — Z (S) $2100
1910.157 D06
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(d)(6): The employer shall distribute portable fire extinguishers or other containers of Class D extinguishing agent for use by employees so that the travel distance from the combustible metal working area to any extinguishing agent is 75 feet (22.9 m) or less. Portable fire extinguishers for Class D hazards are required in those combustible metal working areas where combustible metal powders, flakes, shavings, or similarly sized products are generated at least once every two weeks. WORKPLACE: The employer did not distribute portable Class D fire extinguishers so that travel distance from the work area to any fire extinguisher was 75 feet or less.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $2450.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices,electronic safety devices, etc. WORKPLACE: The unused portion of the saw blade on the Hem Saw, no serial numbers, horizontal band saw was unguarded.
Recent events (2)
- — I (S) $2450
- — Z (S) $3500
1910.38 B
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.38(b): An emergency action plan must be in writing, kept in the workplace, and available to employees for review. WORKPLACE:The employer's emergency evacuation plan was not in writing.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.39 B
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.39(b): A fire prevention plan must be in writing, be kept in the workplace, and be made available to employees for review. WORKPLACE: The employer's fire prevention plan was not in writing.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 336413)
WOODS CROSS, UT—2026-07-16
MATCO MANUFACTURING
NORTH HOLLYWOOD, CA—2026-07-08
AVIBANK MANUFACTURING, INC
SALT LAKE CITY, UT—2026-07-08
NAMMO COMPOSITE SOLUTIONS
SALT LAKE CITY, UT—2026-07-02
BOEING COMPANY
TACOMA, WA—2026-07-01
WA317991845 - PRECISION MACHINE WORKS INC
More inspections in CT
ENFIELD, CT—2026-07-16