2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: FOREST SERVICE, SALMON-COBALT RANGER DISTRICT

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FOREST SERVICE, SALMON-COBALT RANGER DISTRICT in 311 MCPHERSON ST. SOUTH, SALMON, ID 83467 (NAICS 924120). OSHA activity number 339068330.

Watch Forest Service, Salmon-Cobalt Ranger District — free Get an email when a new federal OSHA severe-injury report for Forest Service, Salmon-Cobalt Ranger District is published. One employer, no account, unsubscribe in one click.
Site address
311 MCPHERSON ST. SOUTH
City
SALMON
State
ID
ZIP
83467
Mailing
311 MCPHERSON ST. SOUTH, SALMON, ID 83467
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
924120
Employees
15
Ownership type
D

6 citations on file for this inspection.

1910.106 D04 III

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $3600.00 · Current $0.00 Reduced
29 CFR 1910.106(d)(4)(iii): Electrical wiring and equipment located in inside storage rooms used for Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 degrees F (37.8 degrees C), was not approved under subpart S of this part for Class I, Division 2 Hazardous Locations; for Category 3 flammable liquids with a flashpoint at or above 100 degrees F (37.8 degrees C) and Category 4 flammable liquids, was not approved for general use.    (a)  Gasoline storage building, on or about May 15, 2013, and at times prior thereto, where used portable gasoline containers are stored (with and without gasoline in them), the Class I Division I wiring was invalidated by the openings in the junction box above the ceiling light.       Note:  Abatement certification is required for this item.
Recent events (2)
  • — A (S) $0
  • — Z (S) $3600

1910.1200 G01

Serious Gravity 1 3 instances 10 exposed
Issued
Abate by
Penalty
Initial $2700.00 · Current $0.00 Reduced
29 CFR 1910.1200(g)(1): The employer did not have a material safety data sheet for each hazardous chemical in use:    (a)  Radios Building, on or about May 15, 2013, and at times prior thereto, electronic cleaning spray with propane-butane blend and propylene glycol methyl ether used to clean electronic equipment.    (b)  Road Crew Shop, on or about May 15, 2013, and at times prior thereto, fuel oil used for heating the building.    (c)  Gasoline Storage Building, on or about May 15, 2013, and at times prior thereto, waterborne polyurethane camouflage coating, with Part B containing hexamethylene diisocyanate.    Note:  Abatement certification is required for this item.
Recent events (2)
  • — A (S) $0
  • — Z (S) $2700

1910.24 F

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.24(f): Rise height and tread width were not uniform throughout any flight of stairs including any foundation structure used as one or more treads of the stairs:  (a)  North, Off-site Storage Area, on or about May 15, 2013, and at times prior thereto, where the wood steps at the doorway were not uniform with the step to the doorway.  Note:  Abatement certification is required for this item.
Recent events (1)
  • — Z (O) $0

1910.37 A03

Other-than-serious 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(a)(3): Exit routes were not free and/or unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route.   (a)  Road Crew Shop, on or about May 15, 2015, and at times prior thereto, the rear exit was through a storage room filled with equipment, obstructing the exit route.  Note:  Abatement certification is required for this item.
Recent events (1)
  • — Z (O) $0

1910.1200 F05 I

Repeat Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $15000.00 · Current $0.00 Reduced
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein:    (a)  Road Crew Shop, on or about May 15, 2013, and at times prior thereto, fuel oil storage tank used for heating the building.    Note:  Abatement certification and documentation are required for this item.    The United States Forest Service, Salmon Challis NF, Jesse Creek Compound, was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.1200(f)(5)(i), which was contained in OSHA inspection number 311574370, citation number Citation 2, item number 8A and was affirmed as a final order on 10-15-2008, with respect to a workplace located at Lost River, 716 West Custer, Makay, Idaho 83251.
Recent events (2)
  • — A (R) $0
  • — Z (R) $15000

1910.1200 F05 II

Repeat Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $30000.00 · Current $0.00 Reduced
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings.    (a)  Road Crew Shop, on or about May 15, 2013, and at times prior thereto, fuel oil storage tank used for heating the building.    Note:  Abatement certification and documentation are required for this item.    The United States Forest Service, Salmon Challis NF, Jesse Creek Compound, was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.1200(f)(5)(ii), which was contained in OSHA inspection number 311578306, citation number Citation 1, item number 3 and was affirmed as a final order on 10-28- 2009, with respect to a workplace located at Jesse Creek Compound at the end of Roosevelt.  and  The United States Forest Service, Salmon Challis NF, Jesse Creek Compound, was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.1200(f)(5)(ii), which was contained in OSHA inspection number 311574370, citation number Citation 2, item number 8B and was affirmed as a final order on 10-15-2008, with respect to a workplace located at Lost River, 716 West Custer, Makay, Idaho 83251.
Recent events (2)
  • — A (R) $0
  • — Z (R) $30000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339068330.