YOUNGWOOD, PA —
OSHA Inspection: ROCK EXCAVATION
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of ROCK EXCAVATION in 17 SOUTH 6TH STREET, YOUNGWOOD, PA 15697 (NAICS 236220). OSHA activity number 339069759.
Where did this inspection happen?
- Establishment
- ROCK EXCAVATION
- Site address
- 17 SOUTH 6TH STREET
- City
- YOUNGWOOD
- State
- PA
- ZIP
- 15697
- Mailing
- 310 DIAMOND ROAD, GROVE CITY, PA 16127
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 25
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.405 A02 II I
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $900.00 Reduced
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(I): Protection was not provided to avoid damage to flexible cords and cables used for temporary wiring which passed through doorways or other pinch points: (a) Jobsite- 17 South 6th Street, Youngwood, PA: On or about May 15, 2013, extension cords were observed running through doors, windows, and run over by the CAT TL943 without protection to avoid damage to the cords.
Recent events (2)
- — I (S) $900
- — Z (S) $1200
1926.404 B01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. (a) Jobsite- 17 South 6th Street, Youngwood, PA: On or about May 15, 2013, employees were using equipment such as circular saws rated at 120V that were powered by flexble cords and not protected by ground fault circuit interrupters.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 236220)
NEWPORT BEACH, CA—2026-07-16
KPRS CONSTRUCTION SERVICES, INC.
CHANDLER, AZ—2026-07-16
SUN STATE BUILDERS
ROCHESTER HILLS, MI—2026-07-16
ICON RESTORATION SERVICES
WAUSAU, WI—2026-07-16
MIRON CONSTRUCTION CO. INC.
PONCE, PR—2026-07-15
FC CONSTRUCTION LLC
More inspections in PA
PHILADELPHIA, PA—2026-07-16
URUS CONSTRUCTION CORPORATION
JEFFERSON HILLS, PA—2026-07-16
MARATHON PETROLEUM COMPANY ASPHALT TERMINAL
SMITHFIELD, PA—2026-07-16
CARLISLE CONSTRUCTION MATERIALS
PITTSBURGH, PA—2026-07-15
DREAM GREENER LAWN & LANDSCAPE
COCHRANTON, PA—2026-07-15
CRAWFORD COUNTY HARDWOODS, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339069759.