2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: PRESSURE LINKS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PRESSURE LINKS in 7171 LOUETTA RD, SPRING, TX 77379 (NAICS 332312). OSHA activity number 339070831.

Watch Pressure Links — free Get an email when a new federal OSHA severe-injury report for Pressure Links is published. One employer, no account, unsubscribe in one click.
Establishment
PRESSURE LINKS
Site address
7171 LOUETTA RD
City
SPRING
State
TX
ZIP
77379
Mailing
7171 LOUETTA RD, SPRING, TX 77379
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
55
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 30 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $2100.00 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:   The employer does not ensure that energy control procedures were developed for the control of potentially hazardous energy.  This violation was observed on or about May 15, 2013 in the facility where operators and maintenance employees were exposed to struck-by and caught-in hazards when performing set-up or maintenance tasks on lathes, band saws and other machines such as but not limited to;   a. CNC Lathe, Clausing Model T4, #R900011   b. CNC Lathe, Clausing Model T4. #R90011  c.  CNC Lathe, Clausing Model 200 #C20549   d.  CNC Lathe, Clausing, Model 100 #C10388   e. Hensaw Band saw Model H90A-B/F #867204  f.  Kaiser Air Screw Machine #1233  g. Hensaw Band Saw-Model H90A-4 #1119112  H. Bar Beveler #98032  I.  CNC Mill, Hass #1094681    Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that it has procedures developed, documented and utilized for the control of potentially hazardous energy.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.305 G02 III

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $2975.00 · Current $1785.00 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:   The employer does not ensure that flexible cords and cables were connected to devices and fittings that would prevent pull from being directly transmitted to joints or terminal screws. This violation was observed on or about  May 15, 2013 at the plant where employees were exposed to electrical hazards on a Harding Polishing Machine power cord where the outer insulation had been pulled back from the plug.         Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that flexible cords and cables were connected to devices and fittings that would prevent pull from being directly transmitted to joints or terminal screws.
Recent events (2)
  • — I (S) $1785
  • — Z (S) $2975

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339070831.