Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: AMERICAN HOLLOW BORING COMPANY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of AMERICAN HOLLOW BORING COMPANY in 1901 RASPBERRY STREET, ERIE, PA 16512 (NAICS 333517). OSHA activity number 339075863.

Watch American Hollow Boring Company — free Get an email when a new federal OSHA severe-injury report for American Hollow Boring Company is published. One employer, no account, unsubscribe in one click.
Site address
1901 RASPBERRY STREET
City
ERIE
State
PA
ZIP
16512
Mailing
1901 RASPBERRY STREET, ERIE, PA 16512
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333517
Employees
17
Ownership type
A

3 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1000.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    A.)  American Hollow Boring Company; main machine shop north - On or about 5/17/13, the lathes (#40 Lehmann) had a lathe head and a point of operation which created flying chips.  The lathe areas where the flying chips were created was not guarded.      B.)  American Hollow Boring Company; main machine shop north - On or about 5/17/13, the lathes  (#40 Lehmann) had a lathe head that turned.  The rotating part was not guarded.    C.)  American Hollow Boring Company; main machine shop north - On or about 5/17/13, the boring machines (#1) had a boring head and a point of operation which created flying chips.  The boring area where the flying chips were created was not guarded.      D.)  American Hollow Boring Company; main machine shop north - On or about 5/17/13, the boring machines (#1) had a boring head that turned.  The rotating part was not guarded.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1600

1910.253 B04 III

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $600.00 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least:      A.)  American Hollow Boring Company - On or about 5/17/13, oxygen and acetylene were being stored on a cart with the gauges attached.
Recent events (2)
  • — I (O) $600
  • — Z (S) $1200

1910.303 G01 II

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:   A.)  American Hollow Boring Company; warehouse, Panel H - On or about 5/17/13, a 55 gallon drum of scrap was located  17 inches in front of an electrical panel box.  The panel box was ued to power the lights in the facility.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View AMERICAN HOLLOW BORING COMPANY's full OSHA safety record →