Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JEFF STANLEY CONSTRUCTION, INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of JEFF STANLEY CONSTRUCTION, INC. in 818 W. COLLEGE STREET, AILEY, GA 30410 (NAICS 236115). OSHA activity number 339078685.

Watch Jeff Stanley Construction, INC. — free Get an email when a new federal OSHA severe-injury report for Jeff Stanley Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
818 W. COLLEGE STREET
City
AILEY
State
GA
ZIP
30410
Mailing
3309 E. 1ST. STREET, VIDALIA, GA 30474
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
6
Ownership type
A

3 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2400.00 · Current $1200.00 Reduced
29 CFR 1926.102(a)(1): Employees shall be provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents.    a) On or about May 21, 2013, and at times prior to, employees were observed using nail gun while installing trusses, not wearing personal eye protective equipment, exposing the employees to eye injuries.        ABATEMENT CERTIFICATION AND DOCUMENTATION IS REQUIRED
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2400

1926.501 B13

Serious Gravity 10 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest system, or an alternative fall protection measure that meets a provision described in paragraph (b) of 29 CFR 1926.501.         a)  On or about May 21, 2013, and at times prior to, the employer did not ensure that employees installing trusses were fall protected by guardrail systems, safety net systems, personal fall arrest systems or, implement a fall protection plan why conventional fall protection was infeasible or created a greater hazard, exposing the employees to fall hazards of  about 10 feet.        ABATEMENT CERTIFICATION AND DOCUMENTATION IS REQUIRED
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1926.1053 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1926.1053(b)(13): The top or top step of a stepladder shall not be used as a step.      a)  On or about May 21, 2013, and at times prior to, employee installing trusses used the top and top step of a stepladder to go up and down, exposing employee to a fall hazard of about 10 feet to the concrete floor.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339078685.