ORANGEBURG, SC —
OSHA Inspection: GROUP III MANAGEMENT, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of GROUP III MANAGEMENT, INC. in 1132 COOK ROAD, ORANGEBURG, SC 29115 (NAICS 236220). OSHA activity number 339082083.
Where did this inspection happen?
- Establishment
- GROUP III MANAGEMENT, INC.
- Site address
- 1132 COOK ROAD
- City
- ORANGEBURG
- State
- SC
- ZIP
- 29115
- Mailing
- P.O. BOX 1393, KINSTON, NC 28503
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 7
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.51 F01
- Issued
- Abate by
- Penalty
- Initial $918.00 · Current $735.00 Reduced
General-duty citation text
29 CFR 1926.51(f)(1): The employer did not provide adequate washing facilities for employees engaged in the application of paints, coatings, herbicides, or insecticides, or in other operations where contaminants may be harmful to the employees. Such facilities were not in near proximity to the worksite and was not equipped as to enable employees to remove such substances: (a) Adequate washing facilities were not provided for employees who were exposed to wet concrete during the pouring, vibrating, and finishing of footers and columns. ABATEMENT CERTIFICATION IS REQUIRED
Recent events (2)
- — I (S) $735
- — Z (S) $918
1926.95 A
- Issued
- Abate by
- Penalty
- Initial $918.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.95(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, were not provided: (a) An employee who assisted in pouring, vibrating, and finishing concrete footers and columns was provided with inappropriate leather gloves to protect his hands from wet concrete. ABATEMENT CERTIFICATION IS REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $918
1910.134 K06
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer: (a) Employees who wore a disposable filtering facepiece respirator on a voluntary basis while sweeping and performing other site work activities had not been provided with the basic advisory information on respirators, as presented in Appendix D. ABATEMENT CERTIFICATION IS REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.1052 C01 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge: (a) Two stairways providing access to the superintendent's job trailer were not equipped with stairrail systems along each unprotected side. ABATEMENT CERTIFICATION IS REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at GROUP III MANAGEMENT, INC.
ORANGEBURG, SC—2013-09-05 00:00:00
GROUP III MANAGEMENT, INC.
COLUMBIA, SC—2013-03-20 00:00:00
GROUP III MANAGEMENT, INC.
GOLDSBORO, NC—2004-06-23 00:00:00
GROUP III MANAGEMENT INC
GREENVILLE, NC—2001-08-27 00:00:00
GROUP III MANAGEMENT, INC.
View GROUP III MANAGEMENT, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236220)
IRVINE, CA—2026-07-13
SNEARY CONSTRUCTION, INC.
IRVINE, CA—2026-07-13
KUKBO DESIGN USA LLC
SIOUX FALLS, SD—2026-07-13
REM CONSTRUCTION SERVICES, LLC
INDIAN ROCKS BEACH, FL—2026-07-10
UNKNOWN CONTRACTOR
SIOUX FALLS, SD—2026-07-10
HENRY CARLSON COMPANY
More inspections in SC
GREENVILLE, SC—2026-07-09
77570 - SHARPSHOOTERS INDOOR RANGE INC
NORTH CHARLESTON, SC—2026-07-09
77569 - RAYCAP INC
SUMMERVILLE, SC—2026-07-09
77568 - RACK ROOM SHOES
DENMARK, SC—2026-07-08
77567 - PEGASUS HOME FASHIONS
ROCK HILL, SC—2026-07-08
77566 - WEST MARINE INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339082083.