Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: EAST WEST INDUSTRIAL ENGINEERING DBA EWIE CO., INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of EAST WEST INDUSTRIAL ENGINEERING DBA EWIE CO., INC. in 5531 RAFE COURT, FLOWERY BRANCH, GA 30542 (NAICS 333512). OSHA activity number 339085326.

Watch East West Industrial Engineering DBA Ewie CO., INC. — free Get an email when a new federal OSHA severe-injury report for East West Industrial Engineering DBA Ewie CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
5531 RAFE COURT
City
FLOWERY BRANCH
State
GA
ZIP
30542
Mailing
5531 RAFE COURT, FLOWERY BRANCH, GA 30542
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333512
Employees
20
Ownership type
A

2 citations on file for this inspection.

1910.147 C06 I C

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3060.00 · Current $1836.00 Reduced
29 CFR 1910.147(c)(6)(i)(C): Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected.  On or about 5/22/13, at the Oakwood facility, the employer did not conduct a periodic inspection of the Lockout Program being utilized that included a review between the inspector and each authorized employee.   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1836
  • — Z (S) $3060

1910.147 C07 I A

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3060.00 · Current $1836.00 Reduced
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation.  On or about 5/22/13, at the Oakwood facility, the employer did not ensure each Authorized employee conducting service and maintenance work in the facility received training in established specific written procedures to ensure those employees understood the applicable hazardous energy sources, the type and magnitude energy availalbe, and the methods and means necessary for energy isolation.   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1836
  • — Z (S) $3060