FLOWERY BRANCH, GA —
OSHA Inspection: EAST WEST INDUSTRIAL ENGINEERING DBA EWIE CO., INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of EAST WEST INDUSTRIAL ENGINEERING DBA EWIE CO., INC. in 5531 RAFE COURT, FLOWERY BRANCH, GA 30542 (NAICS 333512). OSHA activity number 339085326.
Where did this inspection happen?
- Establishment
- EAST WEST INDUSTRIAL ENGINEERING DBA EWIE CO., INC.
- Site address
- 5531 RAFE COURT
- City
- FLOWERY BRANCH
- State
- GA
- ZIP
- 30542
- Mailing
- 5531 RAFE COURT, FLOWERY BRANCH, GA 30542
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333512
- Employees
- 20
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C06 I C
- Issued
- Abate by
- Penalty
- Initial $3060.00 · Current $1836.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i)(C): Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected. On or about 5/22/13, at the Oakwood facility, the employer did not conduct a periodic inspection of the Lockout Program being utilized that included a review between the inspector and each authorized employee. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $1836
- — Z (S) $3060
1910.147 C07 I A
- Issued
- Abate by
- Penalty
- Initial $3060.00 · Current $1836.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation. On or about 5/22/13, at the Oakwood facility, the employer did not ensure each Authorized employee conducting service and maintenance work in the facility received training in established specific written procedures to ensure those employees understood the applicable hazardous energy sources, the type and magnitude energy availalbe, and the methods and means necessary for energy isolation. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $1836
- — Z (S) $3060
More inspections in this industry (NAICS 333512)
HATTON, KY—2025-09-25
68430 - CAPITAL CITY TOOL INC
HOUSTON, TX—2025-06-17
MAZAK CORPORATION
MINNEAPOLIS, MN—2025-06-11
109309 - DECONICK INC DBA OPA MACHINING TECHNOLOGY
RED WING, MN—2025-02-13
108783 - MACTECH INC
MARION, NC—2024-12-04
157895 - TOOLCO INDUSTRIAL CORPORATION
More inspections in GA
GREENSBORO, GA—2026-07-16
PURE BEAUTY FARMS, INC.
FOREST PARK, GA—2026-07-16
POLYNT COMPOSITES USA INC.
AUGUSTA, GA—2026-07-16
GF CASTING SOLUTIONS AUGUSTA, LLC
CHAMBLEE, GA—2026-07-16
U.S. DEPARTMENT OF TREASURY
DECATUR, GA—2026-07-15
PALLETS ACQUISITION LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339085326.