Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: MAUI COFFEE ROASTERS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MAUI COFFEE ROASTERS in 444 HANA HIGHWAY, KAHULUI, HI 96732 (NAICS 311920). OSHA activity number 339088510.

Watch Maui Coffee Roasters — free Get an email when a new federal OSHA severe-injury report for Maui Coffee Roasters is published. One employer, no account, unsubscribe in one click.
Site address
444 HANA HIGHWAY
City
KAHULUI
State
HI
ZIP
96732
Mailing
444 HANA HIGHWAY, KAHULUI, HI 96732
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311920
Employees
23
Ownership type
A

3 citations on file for this inspection.

1910.219 D01

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $1600.00 · Current $1200.00 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):   This violation was observed on or about May 24, 2013, where employees used a coffee flavoring floor mixer with an unguarded belt and pulley.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $1600

1910.219 E01 I

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o):(a) (LOCATION) (IDENTIFY SPECIFIC OPERATION(S) AND/OR CONDITIONS) (DESCRIBE HAZARD(S) WHERE NECESSARY)  This violation was observed on or about May 24, 2013, where employees used a coffee flavoring floor mixer with an unguarded belt and pulley.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B02 I

Other-than-serious 1 instance 3 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:  On or about May 29th, 2013, the employer did not protect the electrical control breakers in a wall mounted panel. the door would not latch closed.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339088510.