OSHA Inspection: POST BROTHERS APARTMENTS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of POST BROTHERS APARTMENTS in 315 N 12TH STREET, PHILADELPHIA, PA 19107 (NAICS 236220). OSHA activity number 339090102.

Watch Post Brothers Apartments — free Get an email when a new federal OSHA severe-injury report for Post Brothers Apartments is published. One employer, no account, unsubscribe in one click.
Site address
315 N 12TH STREET
City
PHILADELPHIA
State
PA
ZIP
19107
Mailing
633 W. RITTENHOUSE STREET, PHILADELPHIA, PA 19144
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
2
Ownership type
A

3 citations on file for this inspection.

1926.403 B02

Serious Gravity 5 2 instances 2 exposed
Issued
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification.  a) Gold Tex Apartments, Staircase #1, 2nd floor - The employer did not install and use type NM-8 wire in accordance with listing, labeling, or certification, thus exposing employees to shock hazards.  Observed on or about May 30th, 2013.  b) Gold Tex Apartments, Staircase #1, 3rd floor - The employer did not install and use type NM-8 wire in accordance with listing, labeling, or certification, thus exposing employees to shock hazards.  Observed on or about May 30th, 2013.  NFPA 70 - Article 334.12(9) - Types NM cables shall not be embedded in poured cement, concrete, or aggregate.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2000

1926.34 C

Serious Gravity 5 2 instances 2 exposed
Issued
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1926.34(c): Means of egress was not continually maintained free of all obstructions or impediments to full instant use in the case of fire or other emergency.    a) Gold Tex Apartments, Staircase #1, 2nd floor - The means of egress through staircase #1 in the center of the building did not remain free from all obstructions or impediments for full and instant use in case of an emergency.  Observed on or about May 30th, 2013.    b) Gold Tex Apartments, Staircase #1, 3rd floor - The means of egress through staircase #1 in the center of the building did not remain free from all obstructions or impediments for full and instant use in case of an emergency.   Observed on or about May 30th, 2013.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.502 B02

Other-than-serious 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.502(b)(2): Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structure members were not installed between the top edge of the guardrail system and the walking/working surface when there was no wall or parapet wall at least 21 inches (53 cm) high.  a) Loading dock on Vine Street side of building - Employees loading material onto a first floor loading dock were exposed to a fall hazard of approximately seven and a half (7.5) feet without the use of a complete guardrail system.  Observed on or about May 30, 2013.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View POST BROTHERS APARTMENTS's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339090102.