Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: JOSE RAMOS SIDING SPECIALIST

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JOSE RAMOS SIDING SPECIALIST in 1804 GAINSVILLE STREET SE, WASHINGTON, DC 20020 (NAICS 238170). OSHA activity number 339106619.

Watch Jose Ramos Siding Specialist — free Get an email when a new federal OSHA severe-injury report for Jose Ramos Siding Specialist is published. One employer, no account, unsubscribe in one click.
Site address
1804 GAINSVILLE STREET SE
City
WASHINGTON
State
DC
ZIP
20020
Mailing
4103 MARBLE LA, FAIRFAX, VA 22033
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
4
Ownership type
A

2 citations on file for this inspection.

1926.451 G01 VII

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.   (a) Top Front Center of Structure - Employees working from scaffold approximately 20' in height attaching vinyl siding not protected from falling on to the concrete stairs, ground and scrap materials below on or about 6/6/13.
Recent events (1)
  • — Z (S) $2000

1926.1053 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.1053(b)(1): 29 CFR 1926.1053(b)(1):     Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigged support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder:    (a) Top Front Center of Structure - Ladder used to gain access to pump jack scaffolding extended approximately 1' in height above surface landing allowing for ladder displacement, on or about 6/6/13.    Abatement Certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.