Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: JOHN CRUCE JR., INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JOHN CRUCE JR., INC. in 3860 S BYRON BUTLER PARKWAY, PERRY, FL 32348 (NAICS 113310). OSHA activity number 339106635.

Watch John Cruce JR., INC. — free Get an email when a new federal OSHA severe-injury report for John Cruce JR., INC. is published. One employer, no account, unsubscribe in one click.
Site address
3860 S BYRON BUTLER PARKWAY
City
PERRY
State
FL
ZIP
32348
Mailing
P.O. BOX 86, PERRY, FL 32348
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
113310
Employees
26
Ownership type
A

10 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2380.00 · Current $1190.00 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    a. On or about June 13, 2013, in the shop, the bit on the drill press was not guarded, exposing employees to rotating and flying parts.
Recent events (2)
  • — I (S) $1190
  • — Z (S) $2380

1910.215 A04

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2975.00 · Current $1486.00 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:    a. On or about June 13, 2013, in the shop, the bench grinder did not have a work rest.
Recent events (2)
  • — I (S) $1486
  • — Z (S) $2975

1910.215 B09

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  a. On or about June 13, 2013, in the shop, the bench grinder did not have a tongue guard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 B02 IV

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2380.00 · Current $1190.00 Reduced
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use:    a. On or about June 13, 2013, in the shop, an oxygen cylinder and an acetylene cylinder did not have valve protection caps in place.
Recent events (2)
  • — I (S) $1190
  • — Z (S) $2380

1910.253 B04 III

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet:  a. On or about June 13, 2013, in the shop, oxygen, acetylene and propylene tanks were stored together, exposing employees to fire hazards.  Abatement Certification and Documentation are not required
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 F02

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1785.00 · Current $892.00 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:    a. On or about June 13, 2013, in the shop, on the wall near the office,  the electrical panel was not labelled to indicate its purpose.
Recent events (2)
  • — I (S) $892
  • — Z (S) $1785

1910.305 B02 I

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:  a. On or about June 13, 2013, underneath the electrical panel, the outlet box did not have a faceplate, exposing the employees to a fire and electrical hazards.  Abatement Certification and Documentation are not required
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.141 D01

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.141(d)(1): Washing facilities were not maintained in a sanitary condition:  a. On or about June 13, 2013, the outside bathroom was very unsanitary.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.141 D02 III

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.141(d)(2)(iii): Lavatories were not provided with hand soap or similar cleansing agent:  a. On or about June 13, 2013, the outside bathroom did not have hand soap, exposing employees to health hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.141 D02 IV

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.141(d)(2)(iv): Lavatories were not provided with individual hand towels or sections thereof, of cloth or paper, warm air blowers or clean individual sections of continuous cloth toweling:  a. On or about June 13, 2013, the outside bathroom did not have hand towels, paper or a blower.  Abatement Certification and Documentation are not required
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339106635.