OSHA Inspection: GRINNELL CABINET MAKERS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GRINNELL CABINET MAKERS, INC. in 169 MILL ST, CRANSTON, RI 02905 (NAICS 321918). OSHA activity number 339116790.

Watch Grinnell Cabinet Makers, INC. — free Get an email when a new federal OSHA severe-injury report for Grinnell Cabinet Makers, INC. is published. One employer, no account, unsubscribe in one click.
Site address
169 MILL ST
City
CRANSTON
State
RI
ZIP
02905
Mailing
169 MILL ST, CRANSTON, RI 02905
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321918
Employees
35
Ownership type
A

5 citations on file for this inspection.

1910.242 B

Other-than-serious 1 instance 1 exposed
Issued
Penalty
Initial $2100.00 · Current $0.00 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  (a): Fabrication area 1: The compressed air of the compressed air gun used for cleaning purposes was not reduced to less than 30 p.s.i, on or about 6-14-13.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2100

1910.304 G05

Serious Gravity 5 1 instance 6 exposed
Issued
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:  (a) Fabrication area 1: The ground pin on the power cord of the Craftsman 15 inch drill press was missing, and thus the path to ground from the drill press was not permanent, continuous, and effective, on or about 6-14-13.
Recent events (2)
  • — I (S) $2800
  • — Z (S) $2800

1910.305 G01 IV

Serious Gravity 5 2 instances 6 exposed
Issued
Penalty
Initial $2800.00 · Current $0.00 Reduced
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv):  (a) Fabrication area 1: The extension cord in use and powering an electric drill was used as a substitute for the fixed wiring of the structure, on or about 6-14-13.  (b) Fabrication area 2: The extension cord in use and powering a Milwaukee Vertical Panel saw was used as a substitute for the fixed wiring of the structure, on or about 6-14-13.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

1910.1200 F05

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $2100.00 · Current $0.00 Reduced
29 CFR 1910.1200(f)(5): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged, or marked with the identity and appropriate hazard warnings regarding the chemicals contained therein:  (a) Fabrication area 1: The employer did not ensure that the bottle of Lacquer, a flammable liquid, was labeled, tagged, or marked with the identity and appropriate hazard warnings regarding the chemicals contained therein, on or about 6-14-13.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2100

1910.178 L06

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): (a) Facility: The employer did not certify that each forklift operator was trained and evaluated in workplace-related topics, as required by this paragraph (l), on or about 6-14-13.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View GRINNELL CABINET MAKERS, INC.'s full OSHA safety record →