Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SUPERIOR MARINE SOLUTIONS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SUPERIOR MARINE SOLUTIONS in 500 ROTARY STREET, HAMPTON, VA 23661 (NAICS 336611). OSHA activity number 339120420.

Watch Superior Marine Solutions — free Get an email when a new federal OSHA severe-injury report for Superior Marine Solutions is published. One employer, no account, unsubscribe in one click.
Site address
500 ROTARY STREET
City
HAMPTON
State
VA
ZIP
23661
Mailing
500 ROTARY STREET, HAMPTON, VA 23661
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336611
Employees
25
Ownership type
A

2 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2380.00 · Current $1785.00 Reduced
29 CFR 1910.23(c)(1): Every open-sided floor or platform 4 feet or more above adjacent floor or ground level shall be guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides except where there is entrance to a ramp, stairway, or fixed ladder. The railing shall be provided with a toeboard wherever, beneath the open sides,  a.) Superior Marine Solutions; Warehouse: On or about 06/12/13, a guardrail system was not provided for employees working on top of the mezzanine, thereby exposed employees to a 9' fall.
Recent events (2)
  • — I (S) $1785
  • — Z (S) $2380

1910.22 D01

Other-than-serious 1 instance 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.22(d)(1): In every building or other structure, or part thereof, used for mercantile, business, industrial, or storage purposes, the loads approved by the building official shall be marked on plates of approved design which shall be supplied and securely affixed by the owner of the building, or his duly authorized agent, in a conspicuous place in each space to which they relate. Such plates shall not be removed or defaced but, if lost, removed, or defaced, shall be replaced by the owner or his agent.  a.)  Superior Marine Solutions; Warehouse: On or about 06/12/13, a plate with the floor load capacity was not affixed to the mezzanine.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339120420.