Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PORFIRIO MARTINEZ

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PORFIRIO MARTINEZ in 1050 E. OAKTON AVE., DES PLAINES, IL 60018 (NAICS 238160). OSHA activity number 339124224.

Watch Porfirio Martinez — free Get an email when a new federal OSHA severe-injury report for Porfirio Martinez is published. One employer, no account, unsubscribe in one click.
Establishment
PORFIRIO MARTINEZ
Site address
1050 E. OAKTON AVE.
City
DES PLAINES
State
IL
ZIP
60018
Mailing
4500 W. 115TH PLACE, ALSIP, IL 60803
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
8
Ownership type
A

6 citations on file for this inspection.

1926.501 B01

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1926.501(b)(1):  Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:      a)  Employees disposing of material from the roof edge were exposed to fall hazards of approximately 22 feet.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1926.501 B10

Serious Gravity 10 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1926.501(b)(10):  Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and fuardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.  Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system:      a)  Employees engaged in roofing activities were exposed to falls of approximately 22 feet.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1926.503 A01

Serious Gravity 5 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1926.503(a)(1):  The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:        a)  Employees were exposed to fall hazards while performing roofing work and the employer did not provide a training program to recognize fall hazards and the procedures to be followed in order to minimize those hazards.       In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.1053 B01

Serious Gravity 5 1 instance 7 exposed
Issued
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1926.1053(b)(1):  When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder.  In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.       a)  Employees were using an extension ladder which did not extend 3 feet above the upper landing being accessed.        No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.1053 B04

Serious Gravity 5 1 instance 7 exposed
Issued
Penalty
Initial $2400.00 · Current $1200.00 Reduced
29 CFR 1926.1053(b)(4):  Ladder(s) were used for purposes other than the purpose for which they were designed:    a)  Employees were exposed to fall hazards while using a wooden A-frame ladder without its metal spreaders or locking devices in the open position.     No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2400

1926.1053 B16

Serious Gravity 5 1 instance 7 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and shall be withdrawn from service until repaired:    a)  Employees were using an A-frame ladder which had damaged rungs and legs.   No abatement certification or documentation is required for this item.