RIDGELAND, MS —
OSHA Inspection: CHRIS MONTILLO
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CHRIS MONTILLO in 104 COMMON PLACE, RIDGELAND, MS 39157 (NAICS 238140). OSHA activity number 339129561.
Where did this inspection happen?
- Establishment
- CHRIS MONTILLO
- Site address
- 104 COMMON PLACE
- City
- RIDGELAND
- State
- MS
- ZIP
- 39157
- Mailing
- 1444 WESTHAVEN BLVD, JACKSON, MS 39209
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 2
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 B01
- Issued
- Abate by
- Penalty
- Initial $1800.00 · Current $1800.00
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows: (a) Right-side of House - On or about June 13, 2013 employees were exposed to a 14 foot fall hazard while working on a scaffold that was not fully decked or planked. There was a 21 inch gap in the boards.
Recent events (1)
- — Z (S) $1800
1926.451 C02
- Issued
- Abate by
- Penalty
- Initial $1800.00 · Current $1800.00
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation. (a) Right-side of House - On or about June 13, 2013 employees were exposed to a fall hazard while working on a scaffold that had no base-plates installed.
Recent events (1)
- — Z (S) $1800
1926.452 C02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.452(c)(2): Frames and panels shall be braced by cross, horizontal, or diagonal braces, or combination thereof, which secure vertical members together laterally. The cross braces shall be of such length as will automatically square and align vertical members so that the erected scaffold is always plumb, level, and square. All brace connections shall be secured. (a) Right-side of House - On or about June 13, 2013 employees were exposed to a fall hazard while working on a scaffold that was not plum and vertical due to the cross-braces not being installed.
Recent events (1)
- — Z (S) $0
1926.451 G01
- Issued
- Abate by
- Penalty
- Initial $2160.00 · Current $2160.00
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers. Note to paragraph (g)(1): The fall protection requirements for employees installing suspension scaffold support systems on floors, roofs, and other elevated surfaces are set forth in subpart M of this part. (a) Right-side of House - On or about June 13, 2013 employees were exposed to a fall hazard while working on a scaffold 14 feet 8 inches above the ground without guardrail system or personal fall arrest system.
Recent events (1)
- — Z (S) $2160
1926.454 B
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.454(b): The employer shall have each employee who is involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question. The training shall include the following topics, as applicable: (a) Construction Site - On or about June 13, 2013 employees were exposed to a fall hazard while working on scaffolds without training on how to assemble, disassemble, repair, maintain and inspect scaffolds.
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 238140)
RENO, NV—2026-07-16
DC MASONRY
WINNETKA, IL—2026-07-15
CHICAGO STUCCO CO.
LODI, NJ—2026-07-15
J & O MASONRY CONTRACTORS
DORAVILLE, GA—2026-07-14
SUDLOW CONCRETE, INC.
FLAGLER BEACH, FL—2026-07-14
PLANET DESIGN SERVICES, INC.
More inspections in MS
LAUREL, MS—2026-07-01
THERMO-KOOL
HORN LAKE, MS—2026-07-01
NEWLY WEDS FOODS, INC.
GAUTIER, MS—2026-07-01
DOUBLE R GAUTIER, LLC
OLIVE BRANCH, MS—2026-06-30
HYVE SOLUTIONS
GAUTIER, MS—2026-06-30
STEVE WILSON ENTERPRISE
Source